background image

DISTRIBUTION AMPLIFIERS

6

ACCESSORIES

8

Model No.

Description

RACK MOUNTING BRACKETS

DA1295SX

Rack/Wall/Furniture Mount Mini-
brackets
(2-"L" shaped brackets)

POWER SUPPLIES

PS5502US

9V 500mA Power Supply for US

PS5512UK

9V 500mA Power Supply for UK

PS5522AU

9V 500mA Power Supply for Australia

PS5532GR

9V 500mA Power Supply for Germany

PS5542JP

9V 500mA Power Supply for Japan

4 BNC to 4 BNC COAXIAL CABLE

CB4100MR

Bulk Cable 4 coaxes (500ft minimum)

CB4103MR

3 feet, 4 BNC to 4 BNC coaxial cable

CB4106MR

6 feet, 4 BNC to 4 BNC coaxial cable

CB4112MR

12 feet, 4 BNC to 4 BNC coaxial cable

CB4125MR

25 feet, 4 BNC to 4 BNC coaxial cable

CB4150MR

50 feet, 4 BNC to 4 BNC coaxial cable

CB4175MR

75 feet, 4 BNC to 4 BNC coaxial cable

CB41100MR

100 feet, 4 BNC to 4 BNC coaxial cable

CB41150MR

150 feet, 4 BNC to 4 BNC coaxial cable

4 BNC to 4 BNC COAX (Super High
Resolution)

CB4300MR

Bulk Cable 4 coaxes (500ft minimum)

CB4306MR

6 feet, 4 BNC to 4 BNC coaxial cable

CB4312MR

12 feet, 4 BNC to 4 BNC coaxial cable

CB4325MR

25 feet, 4 BNC to 4 BNC coaxial cable

CB4350MR

50 feet, 4 BNC to 4 BNC coaxial cable

CB4375MR

75 feet, 4 BNC to 4 BNC coaxial cable

CB43100MR

100 feet, 4 BNC to 4 BNC coaxial cable

FREQUENTLY ASKED QUESTIONS

9

No:

Question

Answer

1

What is the
maximum length
of cable that can
be used with the

DA1913GL

?

Compensation for cable
loss is automatically
made for a distance of
100 feet, though the

DA1913GL

 can drive

signals through longer
runs depending on the
source signal resolution
and cable quality.

2

Can I use the

DA1913GL

power supply to
power 2 units
simultaneously?

It is not recommended
since one power supply
is supplied with each
unit. Please consider
the 

PS5581SM

, a rack

mount power supply.

3

Are outputs 1 & 2
buffered?

The 

DA1913GL

 has two

individually buffered
outputs.

4

What is common
mode range of
the 

DA1913GL

and why is it so
important?

The common mode
range of the 

DA1913GL

Distribution Amplifier is
+/-2V with a video signal
of 1V p-p. In most
cases, a ground loop
voltage will not exceed
200-300mV, so this
range is more than
enough to handle even
the most severe ground
loop problems.

5

How will the

DA1913GL

provide protection
from a ground
loop in the
system?

A ground loop is a type
of electromagnetic
interference often
caused by small, but
significant differences in
ground voltage between
two or more different
power sources when
equipment using the
different power sources
is connected by means
of video/audio inputs
and outputs. A ground
loop may also be
caused when high

Summary of Contents for DA1913GL

Page 1: ...DISTRIBUTION AMPLIFIERS MANUAL PART NUMBER 400 0038 003 PRODUCT REVISION 0 DA1913GL 1 IN 2 OUT RGBS DISTRIBUTION AMPLIFIER USER S GUIDE ...

Page 2: ...nding audio visual installations at very competitive pricing We appreciate your selection of our products and are confident that you will join the ranks of our many satisfied customers throughout the world This manual covers DA1913GL 1 in 2 out RGBS Distribution Amplifier with Ground Loop Isolation TABLE OF CONTENTS Page PRECAUTIONS SAFETY WARNINGS 2 GENERAL 2 RACK MOUNT SAFETY GUIDELINES 2 INSTAL...

Page 3: ... top of the DA1913GL If the DA1913GL is to be mounted to a table or wall use only Altinex made mounting accessories like mini mount bracket DA1295FC and cables for optimum setup To turn off the main power be sure to remove the cord from power outlet The power outlet socket should be installed as near to the equipment as possible and should be easily accessible Do not pull power cord or any cable t...

Page 4: ...V 500mA DC power The DA1913GL does not come with a power adapter it has to be wired to a power source using the bare leads The DA1913GL is extremely compact allowing it to fit nicely into tight spots It may also be mounted to almost any surface using optional L type mini brackets Note A power adapter for the DA1913GL must be ordered separately if required In the United States the PS5502US Power Ad...

Page 5: ...3dB Common Mode Rejection 2V w signal of 1V Coupling AC Cross talk 40dB 10MHz Power External Power Adapter AC 9V 500 mA Power Consumption Table 3 DA1913GL Electrical DESCRIPTION OF DA1913GL 4 4 1 POWER The DA1913GL requires the use of a 9 12V DC 500mA power supply The DA1913GL is provided with a hard wired 12 inch power input cable with bare leads on the end 4 2 MOUNTING THE DA1913GL To mount the ...

Page 6: ...he DA1913GL The monitors or projectors must be scan rate compatible with the source signal resolution The DA1913GL does not affect the scan rate Step 4 If the image is less than perfect check all the connections The unit is very reliable and seldom will this be the cause of malfunction Poor quality cables may degrade the performance of the product Make sure that the cables used are coaxial cables ...

Page 7: ...R 100 feet 4 BNC to 4 BNC coaxial cable FREQUENTLY ASKED QUESTIONS 9 No Question Answer 1 What is the maximum length of cable that can be used with the DA1913GL Compensation for cable loss is automatically made for a distance of 100 feet though the DA1913GL can drive signals through longer runs depending on the source signal resolution and cable quality 2 Can I use the DA1913GL power supply to pow...

Page 8: ...ther assumes nor authorizes any other person to assume for it any other liability in connection with the sale of the products This warranty shall not apply to any product that shall have been repaired or altered outside of company s factory in any way so as in its judgment to affect its stability or reliability or that has been subject to misuse negligence or accident 11 2 RETURN POLICY It is very...

Reviews: