background image

DISTRIBUTION AMPLIFIERS

4

Sync on Green

-0.3V

Impedance

10k Ohms

Output Video Signals

Analog Signal

1.0V p-p/0.7V p-p

Fall/Rise Time (ns)

1.4

Impedance

75 Ohms

Output Sync Signal

Composite Sync

TTL(+/-)

Sync on Green

-0.3V

Impedance

22 Ohms

Frequency Compatibility

Horizontal

15-200 kHz

Vertical

47-180Hz

Minimum Video Bandwidth

350 MHz @ -3dB

Typical Video Bandwidth

380 MHz @ -3dB

Common Mode Rejection

+/-2V (w/signal of 1V)

Coupling

AC

Cross-talk

-40dB @ 10MHz

Power

External Power Adapter (AC)

9V 500 mA

Power Consumption

Table 3. 

DA1913GL

 Electrical

DESCRIPTION OF DA1913GL

4

4.1 POWER

The 

DA1913GL 

requires the use of a 9-12V DC

500mA power supply. The 

DA1913GL

 is provided

with a hard-wired 12-inch power input cable with
bare leads on the end.

4.2 MOUNTING THE DA1913GL

To mount the 

DA1913GL

, Altinex offers "L" shape

mini-brackets, 

DA1295SX

, which provide wings on

either side of the unit, allowing it to be installed on
a rack plate, furniture, or a wall.

Summary of Contents for DA1913GL

Page 1: ...DISTRIBUTION AMPLIFIERS MANUAL PART NUMBER 400 0038 003 PRODUCT REVISION 0 DA1913GL 1 IN 2 OUT RGBS DISTRIBUTION AMPLIFIER USER S GUIDE ...

Page 2: ...nding audio visual installations at very competitive pricing We appreciate your selection of our products and are confident that you will join the ranks of our many satisfied customers throughout the world This manual covers DA1913GL 1 in 2 out RGBS Distribution Amplifier with Ground Loop Isolation TABLE OF CONTENTS Page PRECAUTIONS SAFETY WARNINGS 2 GENERAL 2 RACK MOUNT SAFETY GUIDELINES 2 INSTAL...

Page 3: ... top of the DA1913GL If the DA1913GL is to be mounted to a table or wall use only Altinex made mounting accessories like mini mount bracket DA1295FC and cables for optimum setup To turn off the main power be sure to remove the cord from power outlet The power outlet socket should be installed as near to the equipment as possible and should be easily accessible Do not pull power cord or any cable t...

Page 4: ...V 500mA DC power The DA1913GL does not come with a power adapter it has to be wired to a power source using the bare leads The DA1913GL is extremely compact allowing it to fit nicely into tight spots It may also be mounted to almost any surface using optional L type mini brackets Note A power adapter for the DA1913GL must be ordered separately if required In the United States the PS5502US Power Ad...

Page 5: ...3dB Common Mode Rejection 2V w signal of 1V Coupling AC Cross talk 40dB 10MHz Power External Power Adapter AC 9V 500 mA Power Consumption Table 3 DA1913GL Electrical DESCRIPTION OF DA1913GL 4 4 1 POWER The DA1913GL requires the use of a 9 12V DC 500mA power supply The DA1913GL is provided with a hard wired 12 inch power input cable with bare leads on the end 4 2 MOUNTING THE DA1913GL To mount the ...

Page 6: ...he DA1913GL The monitors or projectors must be scan rate compatible with the source signal resolution The DA1913GL does not affect the scan rate Step 4 If the image is less than perfect check all the connections The unit is very reliable and seldom will this be the cause of malfunction Poor quality cables may degrade the performance of the product Make sure that the cables used are coaxial cables ...

Page 7: ...R 100 feet 4 BNC to 4 BNC coaxial cable FREQUENTLY ASKED QUESTIONS 9 No Question Answer 1 What is the maximum length of cable that can be used with the DA1913GL Compensation for cable loss is automatically made for a distance of 100 feet though the DA1913GL can drive signals through longer runs depending on the source signal resolution and cable quality 2 Can I use the DA1913GL power supply to pow...

Page 8: ...ther assumes nor authorizes any other person to assume for it any other liability in connection with the sale of the products This warranty shall not apply to any product that shall have been repaired or altered outside of company s factory in any way so as in its judgment to affect its stability or reliability or that has been subject to misuse negligence or accident 11 2 RETURN POLICY It is very...

Reviews: