background image

DISTRIBUTION AMPLIFIERS

2

PRECAUTIONS / SAFETY WARNINGS

1

Please read this manual carefully before using your

DA1913GL

 Distribution Amplifier. Keep this manual

handy for future reference. These safety
instructions are to ensure the long life of your

DA1913GL 

and to prevent fire and shock hazard.

Please read them carefully and heed all warnings.

1.1 GENERAL

 Unauthorized personnel shall not open the unit

since there are high-voltage components inside.

 Qualified Altinex service personnel, or their

authorized representatives must perform all
service.

1.2 SAFETY GUIDELINES FOR THE RACK-
MOUNTING OF THE DA1913GL

 Maximum operating ambient temperature is 35

(degrees C).

 Never restrict the air flow through the devices’

fan or vents.

 When installing equipment into a rack, distribute

the units evenly. Otherwise, hazardous
conditions may be created by an uneven weight
distribution.

 Connect the unit to a properly rated supply

circuit.

 Reliable Earthing (Grounding) of Rack-Mounted

Equipment should be maintained.

1.3 INSTALLATION

 For best results, place the 

DA1913GL

Distribution Amplifier on a flat, level surface in a
dry area away from dust and moisture.

 To prevent fire or shock, do not expose this unit

to rain or moisture. Do not place the 

DA1913GL

Distribution Amplifier in direct sunlight, near
heaters or heat radiating appliances, or near any
liquid. Exposure to direct sunlight, smoke or
steam can harm internal components.

 Handle the 

DA1913GL

 Distribution Amplifier

carefully. Dropping or jarring can damage
internal components.

 Do not place heavy objects on top of the

DA1913GL

. If the 

DA1913GL

 is to be mounted,

to a table or wall, use only Altinex made

mounting accessories like mini mount-bracket
(

DA1295FC

) and cables for optimum setup.

 To turn off the main power, be sure to remove

the cord from power outlet. The power outlet
socket should be installed as near to the
equipment as possible, and should be easily
accessible.

 Do not pull power cord or any cable that is

attached to the 

DA1913GL

 Distribution

Amplifier.

 If the 

DA1913GL

 Distribution Amplifier is not to

be used for an extended period of time,
disconnect the power cord from the power
outlet.

1.4 CLEANING

 Unplug the 

DA1913GL

 power cord before

cleaning. Clean surfaces with a dry cloth. Never
use strong detergents or solvents such as
alcohol or thinner. Do not use a wet cloth or
water to clean the unit.

1.5 FCC / CE NOTICE

 This device complies with Part 15 of the FCC

Rules. Operation is subject to the following two
conditions: (1) This device may not cause
harmful interference, and (2) this device must
accept any interference received, including
interference that may cause undesired
operation.

 This equipment has been tested and found to

comply with the limits for a Class A digital
device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable
protection against harmful interference when the
equipment is operated in a commercial
environment. This equipment generates, uses,
and can radiate radio frequency energy and, if
not installed and used in accordance with the
instruction manual, may cause harmful
interference to radio communications. Operation
of this equipment in a residential area is likely to
cause harmful interference in which case the
user will be required to correct the interference
at his own expense.

Summary of Contents for DA1913GL

Page 1: ...DISTRIBUTION AMPLIFIERS MANUAL PART NUMBER 400 0038 003 PRODUCT REVISION 0 DA1913GL 1 IN 2 OUT RGBS DISTRIBUTION AMPLIFIER USER S GUIDE ...

Page 2: ...nding audio visual installations at very competitive pricing We appreciate your selection of our products and are confident that you will join the ranks of our many satisfied customers throughout the world This manual covers DA1913GL 1 in 2 out RGBS Distribution Amplifier with Ground Loop Isolation TABLE OF CONTENTS Page PRECAUTIONS SAFETY WARNINGS 2 GENERAL 2 RACK MOUNT SAFETY GUIDELINES 2 INSTAL...

Page 3: ... top of the DA1913GL If the DA1913GL is to be mounted to a table or wall use only Altinex made mounting accessories like mini mount bracket DA1295FC and cables for optimum setup To turn off the main power be sure to remove the cord from power outlet The power outlet socket should be installed as near to the equipment as possible and should be easily accessible Do not pull power cord or any cable t...

Page 4: ...V 500mA DC power The DA1913GL does not come with a power adapter it has to be wired to a power source using the bare leads The DA1913GL is extremely compact allowing it to fit nicely into tight spots It may also be mounted to almost any surface using optional L type mini brackets Note A power adapter for the DA1913GL must be ordered separately if required In the United States the PS5502US Power Ad...

Page 5: ...3dB Common Mode Rejection 2V w signal of 1V Coupling AC Cross talk 40dB 10MHz Power External Power Adapter AC 9V 500 mA Power Consumption Table 3 DA1913GL Electrical DESCRIPTION OF DA1913GL 4 4 1 POWER The DA1913GL requires the use of a 9 12V DC 500mA power supply The DA1913GL is provided with a hard wired 12 inch power input cable with bare leads on the end 4 2 MOUNTING THE DA1913GL To mount the ...

Page 6: ...he DA1913GL The monitors or projectors must be scan rate compatible with the source signal resolution The DA1913GL does not affect the scan rate Step 4 If the image is less than perfect check all the connections The unit is very reliable and seldom will this be the cause of malfunction Poor quality cables may degrade the performance of the product Make sure that the cables used are coaxial cables ...

Page 7: ...R 100 feet 4 BNC to 4 BNC coaxial cable FREQUENTLY ASKED QUESTIONS 9 No Question Answer 1 What is the maximum length of cable that can be used with the DA1913GL Compensation for cable loss is automatically made for a distance of 100 feet though the DA1913GL can drive signals through longer runs depending on the source signal resolution and cable quality 2 Can I use the DA1913GL power supply to pow...

Page 8: ...ther assumes nor authorizes any other person to assume for it any other liability in connection with the sale of the products This warranty shall not apply to any product that shall have been repaired or altered outside of company s factory in any way so as in its judgment to affect its stability or reliability or that has been subject to misuse negligence or accident 11 2 RETURN POLICY It is very...

Reviews: