Micro VoIP 200
User Manual
v1.53
22
4.1.1 General
Language:
The current language of the web page and voice message.
WAN IP:
displayed current WAN IP address of ComCenter-200.
LAN IP:
displayed current LAN IP address of ComCenter-200.
Port
: The ComCenter-200 works as a SIP proxy server for the other SIP devices, any SIP devices
can register to ComCenter-200 to the WAN IP or LAN IP addresses, you can change the port of this
proxy server by modifying the
Port
field in the IP PBX Configuration page. The default value is
5060. The allowed value for this field is between 1 and 65535.
RTP Port Range
: This is the range of ports used by the ComCenter-200 for RTP transmission and
reception. All the calls routed through ComCenter-200, including call to auto-attendant, will have
the RTP port in this range.
Remote/PBX Codec
: ComCenter-200 will determine the remote call codec by this selection. Also
the IP Phone will use this codec to access the voicemail and IVR.
DTMF
: This is the DTMF relay detection method used by ComCenter-200 when a call is connected
between registered devices. ComCenter-200 cannot support
Inband
DTMF when the
Remote/PBX
Codec
is G.723 or G.729.
Authentication
: This field can determine if the other SIP devices needed to be authenticated if they
try to register to ComCenter-200. If this field is enabled, only those devices with the correct
accounts listed in the User Management page are allowed to register into ComCenter-200
Concurrent Calls per User
: This is the max allowed calls for a single IP Phone in the same time. If
want the call waiting function to work, set this filed to a value bigger than two.
Maximum System Parallel Call
: This is the max allowed calls for the whole ComCenter-200
system in the same time, that includes inter-extension calls and incoming and outgoing calls. The
allowed value for this field is between 1 and 60.
Inter-PBX Call in Prefix
: This is the prefix number for incoming call from other ComCenter-200,
with this prefix, the calls between ComCenter-200 could be like an inter-extension calls. The way it
works like this - the dialed number outside of the other ComCenter-200 will be prefixed with this
prefix number , and before incoming into this ComCenter-200, this prefix number will be removed,
and call into the specific extension number.