GM 140 

   File: GM140_r0eng -  October 2003 - Technical note: GM 140                                                                                                                              

         

page     3  

of  12 

Contents

A

Alarms 12

C

CE Declaration  1

Cleaning  7

Components Layout  8

Components List  8

E

Environmental conditions  4

Equipment installation  4

Equipment Ratings  3

F

Fuses replacement  7

Fuses specifications  4

G

General Description  3

General Information  2

H

Handling instructions  4

How to order  12

O

Outside dimensions  9

P

Physical characteristics  4

Pin out of CONN. # 1,2, 3  con segnale esterno   10

Pin out of CONN. # 1,2, 3  con segnale interno   11

   

T

Technical Assistance  12

W

Warnings  2

Wiring   instructions  4

General Informations

This equipment satisfy the European Standard EN 61010-

1 (=CEI 66-5) (=IEC 1010-1) approved by CENELEC on 

9/3/1993.

With reference to EN 61010-1 standard, note:

this appliance must be installed and serviced only by quali-

fied personnel.

The appliance must only be used by persons acquainted 

with the regulations covering the application.

Note about EMC regulation: the generic emission standard 

EN50081-2 (title: Electromagnetic compatibility - Generic 

emission standard - Part 2: Industrial environment) sets 

that “Where a relevant dedicated product or product-family 

EMC emission standard exists, it shall take precedence over 

all aspects of this generic standard”. 

The equipments described in this manual have been clas-

sified as industrial, scientific and medical (ISM) radio-

frequency equipments and the related standard for the 

emission is the EN55011 (=CEI110-6) (title: Limits and 

methods of measurement of radio disturbance characteri-

stics of  ISM equipment.)

With reference to EN55011 standard, this equipment is 

included into Group 2 (Microwave generators, Thyristor 

command equipment, Welding equipment, Induction 

heating equipment or machine, Microwave industrial oven, 

etc.), Class A (industrial environment): for this reason this 

equipment shall not be used in the residential, commercial 

and light-industrial environment.

The GM140, when properly installed, complies with the 

limits of radio disturbance characteristic of a Group2, Class 

A equipments as stated by EN55011.

Copy of the tests performed may be sent on request. Be 

aware those tests cannot be used as a conformity certificate 

of the user’s final equipment.

WARNINGS

The GM140 is a microwave generator with 

output power of 0.3 kW @ 2.45 GHz.

People must not be exposed to the microwave 

energy which may be given off  by the magne-

tron or other microwave generator devices in 

case of incorrect use or connections.

All microwave input and output connections, 

waveguides,  flanges,  and couplings must be 

made safe.

Summary of Contents for GM 140

Page 1: ...GM 140 SWITCHING POWER GENERATOR WITH PULSED OUTPUT CAPABILITY FOR 0 9 KW MAGNETRON 1 5 KW PEAK POWER TECHNICAL NOTE Issue October 2003...

Page 2: ...he il Prodotto product name GM140 nome del prodotto GM140 model GM140T modello GM140T Complies with the following norms Soddisfa le seguenti norme EN 61010 1 1994 A2 1996 EN 61010 1993 A2 1995 EN55011...

Page 3: ...rd exists it shall take precedence over all aspects of this generic standard The equipments described in this manual have been clas sified as industrial scientific and medical ISM radio frequency equi...

Page 4: ...140 may drive the magnetron to reach peak power up to 1 5kWrf with a duty factor of 20 max corresponding to an average power of 300Wrf FRONT PANEL The front panel comprises the following see drw the e...

Page 5: ...y operations the following rules must be adopted I the equipment must be grounded by the connector CONN 1 using the pin n 4 see the wiring drawings at page 10 and 11 II the three phase main supply typ...

Page 6: ...r for pin15 13 GROUND 14 GROUND 15 24 V ISOL In External Insulated 24 Vdc 16 MICROWAVE IS ACTIVATED Out mirror for pin3 17 HIGH VOLTAGE IS ACTIVATED Out mirror for pin2 18 unused 19 MW MODULE IS READY...

Page 7: ...nuous Pin 5 CONN 3 CW PULSE MODE OFF Pulsed with external generator Pin 5 CONN 3 CW PULSE MODE ON Pin 9 10 CONN 3 PULSE PATTERN PWM Amplitude 24 Vdc ton 0 1 10ms toff 1 100ms Max Duty Cycle 20 with hy...

Page 8: ...remove the cover locate the interface board M284 see drawing next page pos 9 locate the fuse on the interface board replace the fuse with a new one with the same electrical characteristics install the...

Page 9: ...pin size lll MOCPCX 0662614 4 Female pin size lll MOCPCX 0667402 6 1 Power board M282 800000282 7 1 Filament transformer 42ATT230 004 8 1 Main filter FL20AY01 9 1 Interface board M284 800000284 1 Conn...

Page 10: ...GM 140 File GM140_r0eng October 2003 Technical note GM 140 page 9 of 12 Outside dimensions...

Page 11: ...GM 140 page 10 of 12 File GM140_r0eng October 2003 Technical note GM 140 Pin out of CONN 1 2 3 with external pulse pattern generator POWER STAGE ON IS ACTIVATED 24V...

Page 12: ...GM 140 File GM140_r0eng October 2003 Technical note GM 140 page 11 of 12 Pin out of CONN 1 2 3 with internal pulse pattern generator POWER STAGE ON IS ACTIVATED 24V...

Page 13: ...rved Technical Assistance Alter s r l 42100 Reggio Emilia ITALY Tel 39 0522 553 820 fax 39 0522 553 577 Web www altersystem com Alarms and warnings When the GM140 is turned on without alarms the ALARM...