background image

Altenburger Electronic GmbH 

                            Manual AQStation Switch V1.0 - 17.07.2015                                                                    Page 4/8

 

6  Technical data 

Designation 

AQStation Switch 

Type 

AQS Switch 

Order Number 

black: 90.00.000 
white: 90.00.001 

Supply Voltage 

230V~ 50Hz, DC not allowed 

Protection 

external 16A, internal microfuse 

Mounting form 

Rail housing 

Dimensions, weight 

WxHxD=121 x 66mm x 56mm, approx. 200 gr. 

Internal displays 

1x green LED (Wi-Fi mode) 
1x green LED (switch mode) on control push-buttons 

Internal controls 

1x push-button for the manual control (on/off) 
1x reset push-button (factory settings, including Wi-Fi) 

Wi-Fi 

2.4 GHz 802.11n 

Operating temperature 

0°C … +30°C 

Power consumption 

< 1.5 W 

Protection class 

I (electrical grounding) 

Protection category 

IP 20 

Degree of contamination 

2 (dry non-conductive) 

Load contact L' (µ) 

Internal relay contact (closing contact) 
Function switching (On/Off), no safe separation (µ  contact opening) 

Loading capacity 

max. 16A~ ohmic load 

Qualification 

CE, RoHS, WEEE 

7  Quick start 

1. 

Download the AQStation App from the store of your choice and install the application. 

2. 

Plug the first AQStation Dimmer / Switch into a socket. Wait up to one minute until the control push-
buttons light up. 

3. 

Connect your smartphone / tablet computer to the AQStation Wi-Fi. Wi-Fi Name: 
„AQStationNewDevice…“. 

4. 

Start the AQStation App. 

5. 

Select your Wi-Fi network and provide the network password (key). 

6. 

The AQ Station device needs about two minutes to load the settings. In the meantime, connect your 
smartphone / tablet computer again to the Wi-Fi. 

7. 

After about two minutes, the new AQStation device will appear in the AQStation App. 

 

 

Summary of Contents for AQStation Switch

Page 1: ...ltenburger Electronic GmbH Manual AQStation Switch V1 0 17 07 2015 Page 1 8 AQStation Switch Typ AQS Switch black Order No 90 00 000 Typ AQS Switch white Order No 90 00 001 LAN Wi Fi based control Manual ...

Page 2: ...y not connect the outputs of multiple AQStation devices Do not rely exclusively on the App s status confirmations as these might differ from the actual status 2 Function The AQStation Switch is a Wi Fi controlled switch It is designed to connect a mains socket 230 V 50 Hz and an electrical load device The module has a 16A volt free relay output It is designed to switch electronic devices of all ki...

Page 3: ...Altenburger Electronic GmbH Manual AQStation Switch V1 0 17 07 2015 Page 3 8 5 Overview Control push button On Off with status confirmation Reset push button Wi Fi Status LED ...

Page 4: ...ection category IP 20 Degree of contamination 2 dry non conductive Load contact L µ Internal relay contact closing contact Function switching On Off no safe separation µ contact opening Loading capacity max 16A ohmic load Qualification CE RoHS WEEE 7 Quick start 1 Download the AQStation App from the store of your choice and install the application 2 Plug the first AQStation Dimmer Switch into a so...

Page 5: ...w establishing connection with your Wi Fi This can take up to two minutes Do not disconnect the AQStation device from power supply Do not interrupt the network connection 11 Go to the settings menu of your smartphone tablet computer select Wi Fi settings and connect your smartphone tablet computer to your Wi Fi 12 Start the AQStation App 13 After a successful initialisation your AQStation device w...

Page 6: ...ssed and re configured Devices can be integrated into multiple scenes Creating a group 1 Groups are created in device settings In the settings menu scroll down until you see Add group and choose this option 2 A new window with group settings will appear 3 Create a new group or choose an existing group 4 Choose New Group 5 Assign a name to the group and choose the building floor and the room in whi...

Page 7: ...ions and timers You can also use the menu to manage the software updates of your AQStation devices 15 Factory settings To make a factory reset of the AQStation device press the reset switch for about 10 seconds with a thin pointed object e g a ball pen refill Do not disconnect the device it takes the device 2 minutes to restart After the restart the AQStation device is restored to its factory sett...

Page 8: ...3 50997 info altenburger de http www altenburger de http www aqstation de All rights reserved It is possible that this manual has undergone pressure technical defects or typographical errors The content of this manual are regularly checked and corrections made in the next issue For technical or printing error type and its consequences we assume no liability Changes in the sense of technical progre...

Reviews: