Alteme Sensonic EDR Operating Instructions Manual Download Page 9

17

16

EN

RESETTING TO FACTORY SETTINGS

1.  Pull out the mains plug
2.   Simultaneously press and hold down the first three buttons (1, 2 

and 3) on the control panel

3.   Plug in the mains plug and continue to hold down the same 

three buttons

4.   After about 5 seconds, all buttons will flash for about 3 seconds 

as confirmation and the buttons can be released

5.   Factory settings restored
The following settings are reset to the factory settings:

 

– All user settings

 

– All HCL curves

 

– All radio buttons (any pre-sets may be deleted) 

 

– All switching times

 

– All network settings

 

– User password will be reset to «1234»

Button 
status

Action

Description

Button follow-up 
status

Light follow-up 
status

Dimming the light field

or

1

3

4

or

Press the button 
for the correspon-
ding channel (1, 
3 or 4) until the 
desired dimming 
level is reached. 
Every time the but-
ton is released, the 
dimming direction 
is reversed.

The corresponding 
button lights up 
orange.

The corresponding 
light field is in «manual 
control» and is no 
longer controlled by the 
automatic system.***

***Note: If only one direct light field is temporarily overridden in the case of the PLATO floor luminaire, the other 
remains in automatic mode – this is indicated by button 2 which is additionally illuminated in white. When both direct 
light fields are in «manual control», the entire light switches to «manual control» – the white LED in button 2 is OFF. 
With the ECO S floor luminaire, the light field which has not been overridden remains at the same dimming level it 
was in before the action was taken. The light switches completely to «manual control mode».

Adjusting the colour temperature 

(Optional function)

2

Press button 2 
until the desired 
colour temperature 
is reached. Each 
further press of the 
button changes 
the direction in 
which the colour 
temperature is 
regulated (from 
cold to warm or 
vice versa).

The LED display of 
button 2 is off.

The light is in «manual 
control» of the colour 
temperature control. 
This means that the 
colour temperature 
remains permanently 
at the set value and no 
longer follows the defi-
ned colour temperature 
curve.****

****Note: As the default setting, manual adjustment of the colour temperature is only possible with direct light. The 
indirect light follows the defined colour temperature curve even when the colour temperature is manually overridden. 
This should prevent different colour temperatures from being visible on the ceiling within a room.

WEBLINK

Operating instructions, assembly instruc-
tions, FAQs and link to app for wireless 
light control and expanded configurati-
ons.

ENHANCED OPERATION

These functions allow users to temporarily override individual light fields. This means that if a specific lighting situa-
tion is to be temporarily adjusted, the individual light fields can be switched on or off individually or dimmed to the 
desired brightness.
Button 
status

Action

Description

Button follow-up 
status

Light follow-up 
status

Switching off the light field

1

3

4

or

or

Briefly press the 
button for the 
corresponding 
channel (1, 3 or 4) .

The corresponding 
button lights up 
orange.

The corresponding 
light field is in «manual 
control» and is no 
longer controlled by the 
automatic system.*

*Note: If only one direct light field is temporarily overridden in the case of the PLATO floor luminaire, the other 
remains in automatic mode – this is indicated by button 2 which is additionally illuminated in white. When both direct 
light fields are in «manual control», the entire light switches to «manual control» – the white LED in button 2 is OFF. 
With the ECO S floor luminaire, the light field which has not been overridden remains at the same dimming level it 
was in before the action was taken. The light switches completely to «manual control mode».

Switching on the light field

1

3

4

or

or

 

– Button 2 «bre-

athes»

 

– Briefly press the 

button for the 
corresponding 
channel (1, 3 
or 4)

The corresponding 
button «breathes» 
orange.

The corresponding 
light field is in «manual 
control reverse mode» 
and is no longer con-
trolled by the automatic 
system.**

**Note: If only one direct light field is temporarily overridden, the other remains in automatic mode – this is indicated 
by button 2 which is additionally illuminated in white. When both direct light fields are in «manual control», the entire 
light switches to «manual control» – the white LED in button 2 is OFF.

PROGRAMMING THE SWITCH-OFF TIME FOR THE MOTION DETECTOR

Action

Description

Control panel status

CAUTION: Switch-off time programming cannot be exited without saving a value. Any user-specific adjustments are 
overwritten.

Step 1

5 sec.

2

+

1

Press and hold down buttons 1 and 
2 together for 5 seconds.

Buttons 1-3 flash. The button which 
corresponds to the currently-set 
switch-off time is constantly lit.*

*Note: If the switch-off time has been configured for the user in the app, none of the buttons will remain constant-
ly lit.

Step 2

or

1

2

3

or

1 = Set to 30 minutes
2 = Set to 15 minutes
3 = Set to 5 minutes
**

While the setting is being saved, 
button 2 flashes rapidly for approx. 3 
seconds.

**Note: Any customer-specific settings are overwritten by the switch-off time programming.

EN

Summary of Contents for Sensonic EDR

Page 1: ...Bedienungsanleitung Mode d emploi Istruzioni per l uso Operating instructions Sensonic EDR...

Page 2: ...ie Leuchte nach der definierten Abschaltzeit automatisch AUS Die Leuchte hat alle m glichen Automatikfunktionen akti viert und befindet sich im sogenann ten AUTO EIN Bereitschafts modus Hinweis Der In...

Page 3: ...App f r die drahtlose Leuchtensteuerung und Konfiguration DE ERWEITERTE BEDIENUNG Mit diesen Funktionen besteht die M glichkeit dass der User einzelne Lichtfelder tempor r bersteuern kann D h wenn vor...

Page 4: ...ement le luminaire s teint automati quement apr s le temps d arr t d fini Le luminaire a activ toutes les fonctions automatiques possi bles et se trouve en mode veille AUTO MARCHE Remarque le mode inv...

Page 5: ...installation Instruc tions de montage FAQ et lien vers l application pour la commande sans fil des luminaires et les configurations avanc es COMMANDE AVANCEE Ces fonctions permettent l utilisateur de...

Page 6: ...o di tempo predefinito per lo spegnimento La lampada ha attivato tutte le funzioni automatiche possibili e si trova nella cosiddetta moda lit stand by AUTO ON Nota la modalit inversa indicata sul pann...

Page 7: ...te funzioni consentono all utente di prendere il controllo e modificare temporaneamente i singoli campi lumino si Ci significa che qualora fosse necessario impostare temporaneamente una specifica situ...

Page 8: ...ht auto matically switches OFF after the selected switch off time The light has activated all possi ble automatic functions and is in AUTO ON standby mode Note Reverse mode is indicated on the control...

Page 9: ...s assembly instruc tions FAQs and link to app for wireless light control and expanded configurati ons ENHANCED OPERATION These functions allow users to temporarily override individual light fields Thi...

Page 10: ...Alteme Licht AG Gysulastrasse 21 CH 5000 Aarau A006780 21 08...

Reviews: