![Alteme Sensonic EDR Operating Instructions Manual Download Page 8](http://html1.mh-extra.com/html/alteme/sensonic-edr/sensonic-edr_operating-instructions-manual_2910744008.webp)
15
14
EN
PROGRAMMING THE SET POINT
Action
Description
Control panel status
Step 1
5 sec.
3
+
2
Press and hold down buttons 2 and
3 together for 5 seconds.
Button 1 is constantly lit orange
Buttons 3 and 4 (in the case of the
4-button panel) flash orange.
Step 2
or
3
4
1
Set the desired set point by means
of a long press of button 3 or 4.
Each new press of the button chan-
ges the dimming direction. Press
button 1 briefly to transfer the value
of the most recently set direct light
field to the other light field.
Step 3
2
Calibrate and save the set point by
pressing button 2.
During calibration, button 2 flashes
rapidly for approx. 3 seconds
Switching off the light
Light
status
Button
status
Action
Description
Light follow-up status
2
Briefly press button 2.
The light is temporarily OFF.
The light is in «reverse mode»,
i.e. as long as the motion
detector detects movement,
the light remains switched off.
If no movement is detected for
more than five minutes, the light
switches to «AUTO ON standby
mode» and will be switched
back on again when movement
is detected once more.*
Switch-off with automatic
presence system.
If no movement is detected
in the detection area of the
motion detector, the light auto-
matically switches OFF after the
selected switch-off time.
The light has activated all possi-
ble automatic functions and is in
«AUTO ON standby mode».
*Note: Reverse mode is indicated on the control panel by orange breathing LEDs on buttons 1, 3 and 4 – button 2
is off.
OPERATING THE LIGHT CONTROL SYSTEM
Switching on the light
Light
status
Button
status
Action
Description
Light follow-up status
2
Briefly press button 2. The
brightness is set automatically
according to the defined set
point.
The light is ON and all possible
automatic functions are active.
The light has activated all pos-
sible automatic functions and is
in «AUTO ON standby mode».
If there is movement in the
motion sensor’s detection area,
the light switches ON automa-
tically when required according
to the current brightness level.
This means that if the light does
not switch on, the external light
or daylight falling on the table,
for example, is brighter than the
set point.
SYMBOLS
Short press of the
control button
Long press of the
control button
«Breathing» LED
LED display OFF
LED display ON,
«AUTO mode»
Status light
ON/OFF
Indirect light field
AUTO
1
2
3
AUTO
2
3
4
1
ON/OFF AUTO
Righthand
direct light field
Lefthand direct
light field
Indirect light field
ON/OFF AUTO
Direct light field
3-button control panel,
ECO S single work-
station version
4-button control panel
PLATO and ECO S 2 and
4 workstation version
EN