background image

#30882-30883 

 trim kit for 2/3 ways thermostatic valve \ plaque pour valve thermostatique 2/3 voies 

 

alt

-aqua.com

3.

Water temperature adjustment

The highest tempature setting has been factory preset 
at 120˚F (49˚C). However, the preset temperature can 
be adjusted by following these steps:

Remove the setscrew (1) and the volume control handle 
(2) (See Fig.4).

Pull out the temperature stop ring (3) from the cartridge. 
Gradually rotate it clockwise to lower the maximum 
temperature or counter clockwise the right to increase 
it.

Once new setting has been adjusted, reassemble 
handle by reversing steps.

Réglage de la température de l'eau

La température maximale a été préréglée en usine à 
120˚F (49˚C). Cependant, cette température peut être
ajustée en suivant ces étapes:

Retirer la vis de retenue (1) et la poignée de contrôle 
de volume (2). (Voir Fig.4).

Ensuite, retirer l'anneau d'arrêt de température (3) de la
cartouche. Tourner l'anneau graduellement dans le 
sens horaire pour diminuer la température maximale et 
anti horaire pour l'augmenter.

Une fois la température réglée, inverser les étapes pour 
réassembler la poignée.

3

2

1

INSTALLATION

 

Fig.4

100°F

38 °C 

Temperature limit stopper

Limitateur de température

 

Fig.5

Summary of Contents for MISTO 30882

Page 1: ...e thermostatique 2 voies partag e non partag e 30882 Via Dante Misto 30892 Via Dante Misto 3 way shared non shared thermostatic valve trim kit Garniture pour valve thermostatique 3 voies partag e non...

Page 2: ...ries regarding Alt products please contact AD WATERS ex clusive distributor of ALT products across North America Canada and USA www ad waters com www alt aqua com F licitations pour l achat de votre p...

Page 3: ...2 voies partag es ABCA TH 300 3 way shared diverter cartridge Cartouche avec d viateur a 3 voies partag es ABCA TH 2LD 2 way non shared diverter cartridge Cartouche avec d viateur a 2 voies non parta...

Page 4: ...BY A LICENSED PLUMBER CAUTION MAKE SURE TO PROPERLY FLUSH THE HOT AND COLD WATER SUPPLY LINES PRIOR TO START ING INSTALLATION MISE EN GARDE POUR OBTENIR UN R SULTAT OPTIMAL NOUS RECOMMANDONS FORTEMEN...

Page 5: ...3 see Fig 1 Insert the diverter cartridge 4 into the valve body as shown Fig 2 Screw the large nut 2 back into place DO NOT OVERTIGHTEN Installation la cartouche Premi rement fermer les 2 valves d ar...

Page 6: ...Fix the trim 10 with the 2 screws supplied 9 Insert the handle 11 14 and tighten with setscrew 12 15 Fig 3 1 12 5 6 7 9 13 14 15 2 4 3 8 10 11 INSTALLATION Intallation de la garniture Ins rer les ext...

Page 7: ...right to increase it Once new setting has been adjusted reassemble handle by reversing steps R glage de la temp rature de l eau La temp rature maximale a t pr r gl e en usine 120 F 49 C Cependant cett...

Page 8: ...rew the large nuts 5 6 the screw 3 back on DO NOT OVERTIGHTEN To reinstall the components just reverse the above steps Entretien de les cartouches Fermer l alimentation d eau principale et d monter to...

Page 9: ...oduits abrasifs chimiques corrosifs incluant de tr s forts d tergents en liquide ou en poudre nettoyants pour vitres et d sinfectants sur votre produit ALT Cela pourrait d t riorer le fini et annuler...

Page 10: ...alt aqua com GARANTIE LIMIT E VIE Les produits ALT sont fabriqu s selon les standards les plus lev s et vous procurerons de nombreuses ann es d usage sans soucis Nous sommes fiers de notre marque et...

Reviews: