background image

#30882-30883 

 trim kit for 2/3 ways thermostatic valve \ plaque pour valve thermostatique 2/3 voies 

 

alt

-aqua.com

1.

Installing the cartridge

First, shut off the 2 check-valves (1),afterwards, unscrew 
the large nut (2) and remove the protective plug (3) 
(see Fig.1) .

Insert the diverter cartridge (4) into the valve body as 
shown (Fig.2). Screw the large nut (2) back into place.
DO NOT OVERTIGHTEN.

Installation la cartouche

Premièrement, fermer les 2 valves d'arrêts (1),dévisser 
ensuite l'ecrou (2) et retirer le
capuchon protecteur (3) (Voir Fig.1).

Insérer la cartouche du déviateur (4) dans la valve tel 
qu'illustré. (Voir Fig.2). Revisser l'ecrou (2) en place.
NE PAS TROP SERRER.

3

2

1

 

Fig.1

4

2

 

Fig.2

INSTALLATION

Summary of Contents for MISTO 30882

Page 1: ...e thermostatique 2 voies partag e non partag e 30882 Via Dante Misto 30892 Via Dante Misto 3 way shared non shared thermostatic valve trim kit Garniture pour valve thermostatique 3 voies partag e non...

Page 2: ...ries regarding Alt products please contact AD WATERS ex clusive distributor of ALT products across North America Canada and USA www ad waters com www alt aqua com F licitations pour l achat de votre p...

Page 3: ...2 voies partag es ABCA TH 300 3 way shared diverter cartridge Cartouche avec d viateur a 3 voies partag es ABCA TH 2LD 2 way non shared diverter cartridge Cartouche avec d viateur a 2 voies non parta...

Page 4: ...BY A LICENSED PLUMBER CAUTION MAKE SURE TO PROPERLY FLUSH THE HOT AND COLD WATER SUPPLY LINES PRIOR TO START ING INSTALLATION MISE EN GARDE POUR OBTENIR UN R SULTAT OPTIMAL NOUS RECOMMANDONS FORTEMEN...

Page 5: ...3 see Fig 1 Insert the diverter cartridge 4 into the valve body as shown Fig 2 Screw the large nut 2 back into place DO NOT OVERTIGHTEN Installation la cartouche Premi rement fermer les 2 valves d ar...

Page 6: ...Fix the trim 10 with the 2 screws supplied 9 Insert the handle 11 14 and tighten with setscrew 12 15 Fig 3 1 12 5 6 7 9 13 14 15 2 4 3 8 10 11 INSTALLATION Intallation de la garniture Ins rer les ext...

Page 7: ...right to increase it Once new setting has been adjusted reassemble handle by reversing steps R glage de la temp rature de l eau La temp rature maximale a t pr r gl e en usine 120 F 49 C Cependant cett...

Page 8: ...rew the large nuts 5 6 the screw 3 back on DO NOT OVERTIGHTEN To reinstall the components just reverse the above steps Entretien de les cartouches Fermer l alimentation d eau principale et d monter to...

Page 9: ...oduits abrasifs chimiques corrosifs incluant de tr s forts d tergents en liquide ou en poudre nettoyants pour vitres et d sinfectants sur votre produit ALT Cela pourrait d t riorer le fini et annuler...

Page 10: ...alt aqua com GARANTIE LIMIT E VIE Les produits ALT sont fabriqu s selon les standards les plus lev s et vous procurerons de nombreuses ann es d usage sans soucis Nous sommes fiers de notre marque et...

Reviews: