HYC_50
– Operation and Installation Guide
Hardware
Version 1-2
4
HYC_50 Installation and commissioning
Page 31 of 76
All rights reserved. Reproduction of this document, in whole or in part, is only permitted with the permission of alpitronic GmbH.
be prevented from being reintroduced into the supply air circuit. Impairments to the air
circulation can lead to a reduction in the charging station's performance.
The minimum distances to obstacles in the supply and exhaust air areas specified in Figure
14 must be observed. If the charging pole is to be installed without barriers, the lower edge
of the display must be within a range of 850 ... 1050 mm above the ground. This is the case
when the uppermost fastening points of the fastening frame are at a height of 1830 mm
above the ground.
The necessary mounting height of the mounting frame is shown in Figure 15.
The following information comes from a publication of the German insurers on loss
prevention (VdS 3471):
-
No highly flammable materials should be stored in the immediate vicinity of the charging
pole.
-
Charging stations are not permitted in fire-hazardous premises in accordance with VdS
2033, explosion-hazardous or explosives-hazardous areas (areas with e.g. explosives
or pyrotechnics) due to the existing hazards.
-
The installation of a fire alarm system is recommended - where appropriate - in order to
detect a fire at an early stage and to fight it in time.
-
When installing in garages, the garage regulations must be taken into account.
-
An additional overvoltage protection device is recommended in the power supply circuit.
Attention
The outlet temperature of the charger's cooling airflow can reach
temperatures up to 75°C
4.1.4. Positioning of mounting frame HYC_50
Figure 15 shows the mounting height for the mounting frame (center of topmost mounting
points) if barrier-free installation is desired.
In this case, the lower edge of the display is at a height of 1020 mm above the floor and thus
the touch buttons on the display are at a height of 1020...1050 mm.
To mount the HYC_50 on the stand as shown in Table 6, first hook the catch on the top into
the retaining point provided. Then screw the bottom of the unit through the holes in the
housing to the stand frame or mounting frame for wall mounting.
By adjusting the screw-on points, existing wall slopes can be compensated for up to an angle
of approx. ± 0.8 degrees (15 mm).
To fix the mounting plate to the wall, M6 screws anchors/dowels with a length of 65 mm are