NUDV – Installation and Operating Instructions
21
Parameter Value
Meaning
Basic
Exam.1 Exam.2
42
z
sign for call extension
ρ
ρ
ρ
z – sign for call extension
ρ
or # (10sec before call end the guard will send a
notice, then the call may be extended)
List of related parameters: 52 8# 84
Parameter Value
Meaning
Basic
Exam.1 Exam.2
43
g bb
command for guard hanging
up from phone
155 266 155 244 155 244
g – command order [1-2] (two commands in order to hang up the guard using
both switches)
bb –
command for guard hanging up from phone
[2 digits]
The advantage is to set the same command both for switch closing (parameter
35) and command to guard hanging up aa=bb.
List of related parameters: 35 8# 84
Parameter Value
Meaning
Basic
Exam.1 Exam.2
44
xxxx
service password
0000
0000
0000
xxxx – service password for entry to programming
List of related parameters: 8# 84
Parameter Value Meaning
Basic
Exam.1 Exam.2
45
dd
command for DAY switching
11
11
11
46
nn
command for NIGHT switching
10
10
10
dd – command for DAY mode switching [2 digits]
nn – command for NIGHT mode switching [2 digits]
Note: The switchover to Day/Night mode remains set in guard even after line
disconnection.
List of related parameters: 1 2 33 34 47 8# 84
Parameter Value
Meaning
Basic
Exam.1 Exam.2
47
e
mode of guard choice
1
1
0
e – mode of guard choice e=0 selects numbers of the first and second
groups, e=1 selects number per Day/Night guard mode.
List of related parameters: 1 2 8# 84
ATTENTION !! This parameter setting will sharply influence the dialing.