NUDV – Installation and Operating Instructions
19
m=3 lighting mode – it will close by guard lifting up and stay closed even for
ss period after guard hanging up (the line is engaged for this period).
m=4 switch mode – it will close after button pressing and open after ss period
(used for e.g. external bell or horn connections).
m=5 gradual opening mode – in this mode the only switch 2 will be set
together with switch 1 set to mode 1. The switch 1 is activated for ss
period, then the time xx is proceeding before switch 2 closing. Then the
switch 2 is activated for ss period and afterwards the guard hangs up.
Note: The only switch 1 can be activated from phone and all sequence started.
Besides that the switch 2 can be separately activated from buttons by password.
List of related parameters: 32 33 34 35 36 37 38 8# 83
Parameter Value
Meaning
Basic
Exam.1 Exam.2
32
r hhhhhh
passw. hhhhhh for switch r
in DAY + NIGHT mode
-
1 121
2 122
1 4561
2 4562
33
r hhhhhh
passw. hhhhhh for switch r
in DAY mode
-
-
-
34
r hhhhhh
passw. hhhhhh for switch r
in NIGHT mode
-
-
-
r
– switch number [1-2]
hhhhhh – password for switch closing from buttons or keyboard [2 to 6 digits]
Total 6 passwords, they are controlled by Day/Night; the combination is
entered either by guard buttons (first 10 buttons) or from attached keyboard
(after pressing of key symbol). The switch closing influences the set switch
mode and Day/Night switchover. By setting of choice mode of 2 number
groups the guard is permanently in DAY mode.
By password choice some rules have to be observed:
Select passwords in way not to find its combination out from wear of
certain buttons by frequent use.
Select the first password button from frequentless button for direct
dialing (-extends choice time)(-not valid for keyboard).
Pay attention to congruity of password numbers when one password
includes other one, e.g. switch 1 has 1234 and switch 2 has 12345.
Then after pressing button 4 the only switch 1 is called, but password
choice 234 for switch 2 can call both switches after pressing switch 4.
Note: The switchover to Day/Night mode remains set in guard even after line
disconnection.
List of related parameters: 31 35 36 37 38 45 46 47 48 49 53 8# 83
Parameter Value Meaning
Basic
Exam.1 Exam.2
35
r aa
command aa from phone after r
switch closing
155 266 155 266 155 266
r
– switch number [1-2]
aa – command from phone after switch closing [2 digits]