![alphainnoTec WZS Series Operating Manual Download Page 26](http://html1.mh-extra.com/html/alphainnotec/wzs-series/wzs-series_operating-manual_2906329026.webp)
26
We reserve the right to modify technical specifications without prior notice.
UK830637/210804 – Translation of the operating manual © Alpha-InnoTec GmbH
removal of the buffer battery
CautIon!
Before scrapping the heating and heat
pump regulator, remove the buffer battery
on the processor board. the battery can
be removed using a side cutter. Dispose
of battery and electronic components
in keeping with environmental
considerations.
removal of the module box
proceed as follows:
Remove insulation.
close angle ball valves.
Attach service hoses from the extra box to the
angle ball valves.
open bleeding valves of the angle ball valves using a
bleeding key and completely empty the module box.
disconnect hydraulic and electric connections.
Raise module box using the straps and lift and pull
from the unit.