Alpha Intec 50CS
3.13 TECHNICAL dATA.
Maximum heat input
kW
33.0
Minimum heat input
kW
7.3
Maximum heat output (useful)
kW
32.0
Minimum heat output (useful)
kW
6.9
Efficiency 80/60 Nom./Min.
%
96.9 / 94.5
Efficiency 50/30 Nom./Min.
%
104.7 / 105.8
Efficiency 40/30 Nom./Min.
%
107.3 / 107.3
Heat loss at casing with burner Off/On (80-60°C)
%
0.80 / 0.20
Heat loss at flue with burner Off/On (80-60°C)
%
0.02 / 2.90
Central heating circuit max. operating pressure
bar
3
Central heating circuit max. operating temperature
°C
90
Max. adjustable central heating temperature
°C
25 - 85
Min. adjustable central heating temperature
°C
25 - 50
System expansion vessel total volume
l
11.7
System expansion vessel factory-set pressure
bar
1.0
Domestic hot water expansion vessel total volume
l
3.0
Domestic hot water expansion vessel factory-/set pressure
bar
2.5
Water content in generator
l
4.0
Total head available with 1000 l/h
m H
2
O
3.61
Hot water production useful heat output
kW
32.0
Domestic hot water adjustable temperature
°C
20 - 60
Domestic hot water circuit flow limiter at 2 bar
l/min
12.6
Min. pressure domestic hot water circuit
bar
0.3
Max. pressure domestic hot water circuit
bar
8.0
*Flow rate 'D' according to EN 625
l/min
19.5
Continuous draw capacity (∆T 30°C)
l/min
15.8
Domestic hot water performance classification according to EN 13203-1
Weight of full boiler
kg
147.7
Weight of empty boiler
kg
90.1
Power supply connection
V/Hz
230/50
Power input
A
0.85
Installed electric power
W
165
Pump consumption
W
34
Fan consumption
W
26.4
Equipment electrical system protection
-
IPX5D
Flue gas max. temperature
°C
75
NO
X
class
-
5
Weighted NO
X
mg/kWh
52
Weighted CO
mg/kWh
17
Type of appliance
C13 / C33 / C43 / C53 / C83 /
C93 / B33 / B53p
Category
II2H3B/P
- Flue temperature values refer to an air inlet
temperature of 15°C and flow temperature of
50°C.
- The data relevant to domestic hot water
performance refer to a dynamic inlet pressure
of 2 bar and an inlet temperature of 15°C, the
values are measured directly at the boiler outlet
to obtain the data declared mixing with cold
water may be necessary.
- * Specific capacity 'D': domestic hot water
flow rate corresponding to an average increase
of 30K, which the boiler can supply in two
successive withdrawals.
To achieve these higher flow rates the flow
restrictor must be removed from the cold inlet
connection. See Section 1.15 item 35.