PM length = C + (1 x 93° bend = 1.3 m) + (2 x 45° bends = 1.8 m)
C
Min.
400 mm
CD Easy-Flue
Flue sealing collar
Terminal end section
from CD Easy-Flue
PM length = C + (2 x 93° bend = 2.6 m) + (2 x 45° bends = 1.8 m)
PM length = C + (4 x 93° bend = 5.2 m)
C
Terminal end section
from CD Easy-Flue
Ensure there is a slope of approximately
3° back towards the Easy-Flue
C
Terminal end
section from
CD Easy-Flue
Fig. 1-14
Note:
The equivalent horizontal flue assembly the equivalent plume management length (PM length) must not exceed the
maximum flue length stated for the boiler, i.e. The boiler maximum equivalent flue length must not exceed 12 metres.
Notes
:
1. Ensure each joint is secured
with the screw supplied.
2. Ensure there is always a
slight slope towards the CD
Easy-Flue so that there is no
part of the pipework where
condensate will collect.