3.11 CASING REMOVAL.
For ease of boiler maintenance the casing can be
completely removed as follows.
• Open the control panel (item 1, Fig. 3-3).
- Press the centre of the control panel cover (2)
to open it and lower the panel.
-
Carefully remove the rubber bump stops (3)
and loosen the two screws (4).
- Step A. Lift the control panel up, gripping it
at the sides, to disengage it from the locking
pin (5).
- Step B. Pull the control panel forwards
slightly.
- Step C. Hinge open the panel as shown in Fig.
3-3.
• Remove the lower panel (item 6, Fig. 3-4).
- Step D. Press down on the two catches (7)
- Step E. Hinge the cover forwards on the two
screws (8) and lift it off the screws.
• Remove the remaing case panels (Fig. 3-5).
- Top cover (item 9, Fig. 3-5). Remove the two
screws (10), pull the cover forwards slightly
to disengage the fixings (see view A) and lift
it off.
- Rear top cover (item 11, Fig. 3-5). Remove
the two screws (12) and lift off the cover.
- Front panel (item 13, Fig. 3-5). Remove the
two screws (14), lift up the cover slightly to
disengage the fixings (see view B) then pull
it forwards off the side panels.
- Side panels (item 16, Fig. 3-5). Remove the
upper and lower screws (15) then slide the
panel forwards to disengage it from the rear
fixings (see view C).