![Alpha InTec 50CS Installation, User And Servicing Instructions Download Page 25](http://html1.mh-extra.com/html/alpha/intec-50cs/intec-50cs_installation-user-and-servicing-instructions_2905186025.webp)
Fig. 3-5
INS
TALL
ATI
O
N
US
ER
MAINTEN
AN
CE
25
Alpha Intec 50CS
View A
View B
View C
12
11
9
10
15
15
16
14
13
14
15
16
3.12 COMBUSTION SETTINGS.
Natural Gas
Propane
Supply pressure
mbar
20
37
Burner nozzle
mm
N/A
6.00
Flue flow rate at max heat output
kg/h
52
53
Flue flow rate at min heat output
kg/h
12
12
CO
2
at Q. Nom./Min.
%
9.40 / 8.90
10.50 / 10.30
CO at 0% di O
2
at Q. Nom./Min.
ppm
206 / 9
190 / 8
NOX at 0% of O2 at Nom.Q./Min.
ppm
83 / 43
99 / 54
Flue temperature at nominal output
°C
73
74
Flue temperature at minimum output
°C
64
66
Gas rate at maximum heat output
m³/h
3.49
N/A
Gas rate at maximum heat output
kg/h
N/A
2.57