Please read these instructions carefully before operating your boiler.

The Alpha E-Tec range of high efficiency condensing boilers incorporate the latest technology in boiler design. With improved 
burner efficiency and reduced electrical consumption together with high quality and reliability.
The boiler output will automatically adjust according to the requirements of the system.
The E-Tec range are designed to work with most central heating controls however we recommend the Alpha Comfort or 
Easy-Stat standard controls or the enhanced Alpha Climatic boiler energy manager further improving the system efficiency 
by varying the system temperature depending on the room temperature and heat losses.
In addition all E-Tec models feature optional connections for an outside sensor to enable the boilers built in weather 
compensation feature. 
The boilers will provide central heating when required during the on times as set according to the controls fitted. Hot water 
will always take priority over the central heating whenever a hot tap is opened.

Fig. 1

2  OPERATING THE BOILER

1 INTRODUCTION

Switch the boiler on at the mains supply socket switch. The boiler will be in either 'Standby' or 'On' mode. 
By pressing the Mode button (item 1 in Fig. 1) the Standby or On mode can be selected, or press and hold the Mode button 
for eight seconds to turn the boiler off. 
Standby - In this mode the boiler will not provide hot water or central heating, but frost protection and pump circulation 
features are still active.
Off - In this mode there is electrical power to the boiler but the boiler will not function in any condition.
On - In this mode the boiler can be switched between 'Summer' or 'Winter' settings by pressing the Mode button (item 1 in 
Fig. 1).

Summer setting - The boiler will only provide hot water when a tap is turned on and the central heating will not activate even 
if requested by external controls (frost protection and pump cycle are still active).
Winter setting - The boiler will operate in both heating and hot water. The heating will activate depending on the time and 
temperature from any heating controls fitted. Hot water will always take priority over heating when a hot outlet tap is opened.

The boiler controls are located on the control panel.Make sure the heating system is filled and the needle on the pressure 
gauge (item 8 in Fig. 1) is in the green band when cold. If incorrect refer to Section 4.

1  - Off/Stand-by/Summer/Winter button 
2  - Information button
3  - Reset Button 
4  - Reduce DHW set temperature 
5  - Increase DHW set temperature 
6  - Increase heating system set temperature 
7  - Reduce heating system set temperature 
8  - Heating system pressure gauge 

9  - Domestic hot water active
10 - Remote Climatic controller fitted
11 - Boiler fired and power level 
12  - External weather probe fitted
13 - Active solar supply (pre-heated inlet)
14 - Central heating active 
15 - Central heating temperature indicator 
16 - Boiler in Stand-by mode 

17 - Winter mode – heating and hot water
18 - Summer mode – DHW only
19 - Temperature/info/code -  display
20 - Not used on this model
21 -  Boiler locked - reset required
22 - DHW temperature indicator

4

5

6

7

8

1

2

3

RESET BOOST

°C

RESET BOOST

°C

9

10

11

12

13

14

15

16

17

18

19

20

21

22

RESET

INFO

Summary of Contents for E-Tec 28

Page 1: ...venoaks Kent TN15 7RS For Technical help or for Service call ALPHA HELPLINE Tel 0844 871 8764 website www alpha innovation co uk Set for use with Natural Gas Leave these instructions with the User These instructions have been carefully prepared but we reserve the right to alter the specification at any time in the interest of product improvement Alpha Therm Limited 2017 ...

Page 2: ...res are still active Off In this mode there is electrical power to the boiler but the boiler will not function in any condition On In this mode the boiler can be switched between Summer or Winter settings by pressing the Mode button item 1 in Fig 1 Summer setting The boiler will only provide hot water when a tap is turned on and the central heating will not activate even if requested by external c...

Page 3: ...and temperature will still be maintained according to the setting of the room thermostat 3 HEATING AND HOT WATER TEMPERATURE Fig 2 External weather compensation probe fitted Flow temperature C External temperature C 27 15 5 5 10 0 10 15 20 25 25 60 40 85 50 Flow temperature in brackets ie 25 to 50 C range when boiler is used with a low temperature system such as under floor heating Setting 1 to 9 ...

Page 4: ...tem for external condensate drainage pipework incorporating an external frost thermostat should be considered 7 GAS SAFETY REGULATIONS Current Gas Safety Installation and Use Regulations It is the law that all gas appliances are installed and serviced by a competent person i e Gas Safe registered personnel Failure to install or service appliances correctly could lead to prosecution It is in your i...

Page 5: ...lt or gas leak is suspected turn off the gas supply Do not touch any electrical switches do not smoke and extinguish all naked flames Contact the National Gas Emergency Service immediately on 0800 111 999 8 ELECTRICAL SUPPLY The boiler requires a 230 240 V 50 Hz supply fused at 3 A To connect a plug The colour of the wires in the mains lead of the boiler may not correspond with the coloured markin...