12.8 FILLING LOOP
With the CombiMax in a remote location from the boiler, the filling loop facility supplied with the boiler cannot be used as
designed. The filling loop should be discarded and its connections on the cold mains inlet valve (CombiMax) and heating return
valve (boiler) sealed, using ½" BSP threaded caps (not applicable to Alpha 240X). See Fig. 16.
12.9 CONNECTING PIPEWORK
The boiler and CombiMax must be connected together as shown in Fig. 16, using 15 mm pipework. The pipework supplied with
the CombiMax can be utilised to provide the connections at the boiler and CombiMax.
12.10 ELECTRICAL SUPPLY
Connect the electrical supply cable directly to the CombiMax terminal block as described in section 4.7,
ensuring
the cable is
secured with the clamping bush supplied.
The cable supplied fitted for connection to the boiler will be too short and therefore
must
be removed from the CombiMax terminal
block terminals 1, 2 and . A longer length cable to the same specification stated in section 3.1 must then be used to connect the
electrical supply to the boiler terminal block from the CombiMax.
Note:
Connect this electrical supply to the boiler as described in the boiler instructions.