2.
Determine the overall length (L) of flue required, (see Fig. 16) as follows:-
Rear flue
L = wall thickness (B) + 170 mm
Side flue
L = wall thickness (B) + distance between boiler and wall (C) + 230 mm
Fig. 16
3.
Adjust the telescopic section of the flue to the distance 'L', ensuring that the two labels marked 'TOP' are aligned, then seal
and secure the joint between the ducts with the sealing tape supplied.
4.
Pass the flue assembly through the wall (from inside or outside).
Note: Internal fitting -
If there is no access to make good the outside wall, locate the flue sealing collar onto the outer duct
of the flue immediately before the terminal grille onto the location provided. Push the flue assembly through the 130 mm flue
hole, so that the collar completely passes through the wall. Then pull the flue assembly back into the correct position. Visually
check that the collar is sealing the outside wall and that it is not restricting any of the openings of the flue terminal.
5.
Position the seal and clamp (two screws) supplied, over the bend. Fit the bend to the boiler and rotate to the correct position.
Secure in position using the seal and clamp, ensuring the seal is located centrally over both the bend and boiler adaptor.
6.
Fit the inside flue sealing collar over the Easy-Flue. Fit the outside flue sealing collar onto the flue immediately before the
terminal grille onto the location provided.
7.
Slide the clamp (three screws) over the outer duct and pull the flue assembly towards the bend, locating the inner duct into
the seal joint on the bend. Ensure the labels marked 'TOP' are positioned at the top before securing the flue assembly to
the bend with the clamp (three screws) located centrally over the joint.
Note:
Check the flue terminal protrudes 100 mm out of the wall and the inner duct of the terminal is positioned correctly
(see Fig. 18).
8.
Make good the inside wall by pushing the inside flue sealing collar upto the wall.
Fig. 17 - Fitting the flue from inside
4.6
FIT THE FLUE - Figs. 14, 15
The following procedure applies to fitting an Alpha CD Easy-Flue to both rear or side exit flue - horizontally only.
1.
The CD Easy-Flues are suitable for use in the flue length ranges shown in the tables below.
Note:
Where the length is less than the minimum or more than the maximum, refer to Section 4.7.
Alpha CD18S/24S/30S - Installation
Fig. 14
Fig. 15
CD Easy-Flue
500 mm
1000 mm
B (mm)
Max
520
915
Min
280
675
CD Easy-Flue
500 mm
1000 mm
Max
460
855
Min
220
615
B + C (mm)
Summary of Contents for Alpha CD18S
Page 29: ...29 9 1 ILLUSTRATED WIRING DIAGRAM Alpha CD18S 24S 30S Wiring Diagrams 9 WIRING DIAGRAMS ...
Page 30: ...30 Alpha CD18S 24S 30S Wiring Diagrams 9 2 FUNCTIONAL FLOW WIRING DIAGRAM ...
Page 32: ...32 10 2 FAULT FINDING SOLUTIONS A to E Alpha CD18S 24S 30S Fault Finding ...
Page 33: ...33 Alpha CD18S 24S 30S Fault Finding 10 3 FAULT FINDING SOLUTIONS F to K ...