background image

 

  

 

Alpha Climatic Programmable Modulating Boiler Energy Manager 

 
 

Part No 3.022144 (Hard Wired) 

         Part No 3.022143 (Radio Frequency) 

 
 
 
 

 

Installation and User Instructions

Summary of Contents for 3.022143

Page 1: ...Alpha Climatic Programmable Modulating Boiler Energy Manager Part No 3 022144 Hard Wired Part No 3 022143 Radio Frequency Installation and User Instructions...

Page 2: ...oiler is via a two core cable to the low voltage bus connection for hard wired version or via an integrated RF receiver for the RF version 2 Mounting of the Controller The controller must be mounted i...

Page 3: ...ar casing hard wired only Re fit the front control panel lower the control cover 1 and secure the control panel using the two 10mm screws provided 3 Note If an RF controller is being used then the dat...

Page 4: ...talling the receiver RF models only Gain access to the boiler terminal block as described in the boiler installation and service instructions section 4 10 Remove the screws from the fixing posts in th...

Page 5: ...y 3 Heating Cooling on off temperatures 4 Reset remote settings 5 Programming menu selection 6 Menu selection 7 DHW temperature set 8 CH temperature set 9 Information e g flow temperature 10 Auto Manu...

Page 6: ...g or cooling Holiday mode Cylinder heating in progress if present Indicates it is possible to adjust a parameter using buttons 11 and 12 Request for DHW 000 000 Describes current status Request for He...

Page 7: ...lash using the buttons set to the correct day of the week and press OK then ESC to get back to main menu b Set Heating Programme Press the button and TIME will appear press and CH PRG will flash press...

Page 8: ...p pressing ESC NOTE if four on off periods are not required then set the unused periods on off times the same E g On 23 00 off 23 00 d Setting the Temperature Note There are two temperature settings c...

Page 9: ...e primary heating water temperature to the user s requirement When the dial is turned the temperature setting is displayed on the screen The primary flow temperature might not reach the temperature se...

Page 10: ...ler will operate at minimum heating output until the room temperature has been raised to 5 6 C g External Probe optional If an external temperature probe is fitted it is possible to set a flow tempera...

Page 11: ...value will be displayed e g DHW T 50 C if a value is not present a will be displayed The display of the INFO is subject to the boiler model and the method of connection of the programmer To get return...

Page 12: ...ontroller or receiver and the boiler ERR TP Climatic Display Error in reading the room temperature or value measured off scale below 0 C or over 50 C E51 Boiler display Communication error between the...

Page 13: ...t can be regulated from 15 C to 15 C and which in the presence of the optional external probe modifies the set flow temperature see fig 5 set as standard at 0 C NOTE if the self leaning function is en...

Page 14: ...bottom of the screen This function can be deactivated by pressing the button In the event of remote telephone activation the Climatic controller will revert back to normal operation omitting the holid...

Page 15: ...to EN 60730 II Protection rating according to EN 60529 IP 20 Connection technique 2 polarised wires Load reserve time 8 hours for hourly count with at least 2 hours of charge Connection cable max leng...

Page 16: ...on polarised wires Connection cable supplied 280 mm with cable of 2x0 35mm2 Controller Data Dimensions LxHxD 142 x 103 x 31 Power Supply 2 x 1 5 V AA batteries Functioning room temperature 0 40 C Ware...

Page 17: ...re 25 C Cooling Economy Temperature 40 C Room Temperature in Manual 20 C Anti Freeze 5 0 C Holiday Program HOLIDY OFF Offset OFFSET 0 C Building Inertia BUILD 10 Self Learning AUTO A OFF Room Probe AM...

Page 18: ...18...

Page 19: ...19...

Page 20: ...eath Sevenoaks Kent TN15 7RS Tel 0844 871 8764 Email info alpha innovation co uk Website www alpha innovation co uk These instructions have been carefully prepared but we reserve the right to alter th...