BRAVE
– user guide
33
Parametr Value
Description
Default
37
r ss
time
ss
[sec] activation relay
r
for time
t1/t4
(01-99)
105 205
r
– relay number [1-2]
ss
– time t1 / t4 for which is relay closed 1 / 2 [2 digits 00-99], where time 00
means 0,5sec
Parametr Value
Description
Default
38
r p
Control relay
r
during incoming call
(0/1)
11 21
r
– relay number [1-2]
p
– parametr which says permitted
p=1
or forbidden
p=0
control relay during
incoming call
To prohibit control of relay during incoming call has a sense for example by
relay2 in mode 1 by which you control sliding gate opening where door intercom
open the gate and after car passing the gate is closed. Then control by phone
could make unwillingly permanent gate opening.
Parametr Value
Description
Default
39
xx
time
xx
[sec] between activation relay 1
and 2 in mode m=5 - time
t3
(01-99)
10
xx
– time t3 between activation relay 1 and 2 when mode
m=5
is setup
(progressive opening) [2 digits 00-99] ], when time 00 means 0,5sec
Parametr Value
Description
Default
30
r zz
time
zz
[sec] between pulses when is
closing for 2 pulses relay
r
- time
t2/t5
(01-99)
105 205
r
– relay number [1-2]
zz
– time t2 / t5 between first and second pulse relay activation 1 / 2 [2 digits
00-99], where 00 means 0,5sec