1. Safety Instructions and Battery Care

1.1.    Safety Instructions

1.1.1.  Because of small leakage currents generated by the EMI filter in the UPS 

it is necessary to double check that the ground wire of the UPS is properly 

grounded before connecting the UPS to the AC mains. 

1.1.2.  To  ensure  safety  in  all  applications  where  a  UPS  is  hard  wired  to  the 

electrical supply, ensure that the system is installed by a qualified electrical 

contractor. 

1.1.3.  The UPS has its own internal energy source (battery). Should the battery 

be switched on when no AC power is available there could be voltage at 

the output terminals. 

1.1.4.  Make sure that the AC utility outlet is correctly grounded. 

1.1.5.  Do not open the case as there are no serviceable parts inside. Opening 

the case voids the warranty. 

1.1.6.  Do not try to repair the unit yourself; contact your local supplier. Repairing 

the unit yourself voids the warranty. 

1.1.7.  Please make sure that the input voltage of the UPS matches the supply 

voltage. 

1.1.8.  Use a certified input power cable with the correct plugs and sockets for the 

appropriate system voltage. 

1.1.9.  To prevent any overheating of the UPS keep all ventilation openings free 

from obstruction, and do not store things on top of the UPS. Keep the UPS 

30 cm away from the wall. 

1.1.10.  Ensure that the UPS is installed within the proper environmental range. (0-

40

°

C and 0-90% non-condensing humidity) 

1.1.11.  Do not install the UPS in direct sunlight. Your warranty may be void if the 

batteries fail. 

1.1.12.  Install the UPS indoors as it is not designed for installation outdoors. 

1.1.13.  Dusty, corrosive and salty environments can damage any UPS. 

1.1.14.  Install the UPS away from objects that give off excessive heat and areas 

that are excessively wet. 

1.1.15.  If liquids are spilt onto the UPS or foreign objects dropped into the unit the 

warranty will be null and void. 

1.1.16.  The battery will discharge naturally if the system is unused for a long time. 

1.1.17.  The UPS should be recharged every 2-3 months if unused. If this is not 

done  then  the  warranty  will  be  null  and  void.  When  installed  and  being 

used  the  batteries  will  be  automatically  recharged  and  kept  in  top 

condition. 

1.1.18.  This  UPS  supports  electronic  equipment  in  office,  telecommunication, 

process-control,  medical,  and  security  applications.  Non-authorized 

technicians are not allowed to install the UPS in the following areas. 

a. Medical equipment directly related to human life

b. Elevators,  subway  systems,  or  any  other  equipment  related  to

human safety.

c. Public systems or critical computer systems.

1.1.19.  Do not install the UPS in an environment with sparks, smoke or hazardous 

gas. 

1.1.20.  Make sure the UPS is completely turned off when transporting it. It might 

cause electrical shock if the output is not cut completely. 

1.1.21.  The  UPS  includes  a  Maintenance  Bypass  Switch.  Please  follow  the 

procedures  strictly  when  switching  on  or  off  the  Maintenance  Bypass 

Switch. 

Page 

3

 to 

4

5

Page 

2

 to 

4

5

Summary of Contents for Continuity 10K

Page 1: ...Continuity 6K 10K USER MANUAL...

Page 2: ...5 3 Installation and Operation 16 3 1 Unpacking 16 3 2 Selecting Installation Position 17 3 3 Installation of Accessories Kit 18 3 4 Terminal Block Explanation 19 3 5 Installation and Operation 23 4 T...

Page 3: ...ondensing humidity 1 1 11 Do not install the UPS in direct sunlight Your warranty may be void if the batteries fail 1 1 12 Install the UPS indoors as it is not designed for installation outdoors 1 1 1...

Page 4: ...parts on top of batteries 5 Disconnect charging source prior to connecting or disconnecting battery terminals 6 Determine if battery is inadvertently grounded If inadvertently grounded remove source f...

Page 5: ...pass mode and vice versa 2 1 7 The fully digitalized control circuit built into the UPS allows upgrading the functionality of the UPS as well as reaching a high level of protection of the UPS Powerful...

Page 6: ...ry charging device k Internal Battery When AC abnormal it provide the backup power from the batteries l External Battery Bank To provide longer backup time by adding additional Battery bank m Inverter...

Page 7: ...hort Circuit 27 Er10 Inverter Over current Item Symbol Description 28 Er11 The UPS is overheated 29 Er12 UPS Output Overloading 30 Er14 Fan Error 31 Er15 Wrong Procedure to Enter Maintenance Mode 32 E...

Page 8: ...ndicates that the utility input voltage is outside the acceptable window Green LED indicates that Bypass Input is normal UPS ON Alarm Silence Go to previous page or change the setting of the UPS Confi...

Page 9: ...1 1 You may use optional interfaces cards for R2E RS 232 RSE RS 485 USE second USB DCE Dry Contact and SNMP However the R2E card RSE card and USE card must not be used simultaneously 2 4 1 2 The softw...

Page 10: ...y but not for moving UPS 3 2 Selecting Installation Position Install the UPS in a proper environment to minimize the possibility of damage to the UPS and to extend the life of the UPS Please follow th...

Page 11: ...e terminals for UPS Output G2 the terminal for UPS Output Ground Remarks 1 The maximum current for each terminal is 36 Arms for 6 kVA 65 Arms for 10 kVA 2 If the UPS is a SIM Single Input type only AC...

Page 12: ...module socket 3 Please refer to the specifications of input current output current and recommended conductors listed below a AC input and output minimum 75 C copper wire b Battery input Page 21 to 45...

Page 13: ...sure the utility voltage matches the input voltage window of the UPS 3 5 1 4 Connect the utility separately to the terminal blocks of the UPS Utility and Bypass inputs Switch on the power breaker of t...

Page 14: ...or error status will appear on the screen 3 5 1 9 Your start up operation of the UPS is complete now Make sure the UPS is plugged into the wall receptacle for charging at least 8 hours and the batteri...

Page 15: ...own the LCD will display figure C Voltage from Utility Input figure I1 Voltage from Bypass Input figure J Frequency from Utility Input figure K Frequency from Bypass Input figure L UPS Output Voltage...

Page 16: ...UPS battery numbers Page 29 to 45 Page 28 to 45 P UPS inner temperature 3 5 4 UPS Default Data and Special Function Execution 3 5 4 1 After the UPS completely starts up press the key to change the LC...

Page 17: ...r Output Voltage figure V1 UPS Operation Mode figure W Output Voltage Micro Tune Value figure X UPS Id figure Y Parallel function status R1 Self test is not On R2 Self test is On S1 Bypass Voltage is...

Page 18: ...in setting mode 3 5 5 2 To scroll through the options refer to section 3 5 4 2 3 5 5 3 Except for Buzzer figures Q1 and Q2 and Self test figures R1 and R2 all of the other default settings may be chan...

Page 19: ...d twice 3 5 6 2 4 Turn Off the Utility Input breaker 3 5 6 2 5 Even if the UPS lock problem is solved now consult with your local distributor to make sure that the error condition is resolved 3 5 7 Sh...

Page 20: ...36 to 45 Situation Check Items Solution red Fault LED Check the error code shown on the LCD 1 Check for proper battery connection then recharge the batteries for 8 hours to see whether the UPS provid...

Page 21: ...lt your local distributor for help Situation Check Items Solution Pin 1 UPS on Bypass mode Pin 2 Utility Abnormal Pin 3 Utility Normal Pin 4 Inverter On Pin 5 Battery Low Pin 6 Battery Bad or Abnormal...

Page 22: ...6 2 DCE Dry Contact C card 6 2 1 Please refer to the New Dry Contact Card English Installation Guide A5 192321002014002 Page 41 to 45 Page 40 to 45 6 3 Interface Card Installation...

Page 23: ...ly Battery Low Battery Bad Disconnect Overload Transferring with interruption UPS Fault Input Voltage Input Frequency Output Voltage Output Frequency Load Percentage Battery Voltage Inner Temperature...

Page 24: ...LCD Line Mode Backup Mode ECO Mode Bypass Supply Battery Low Battery Bad Disconnect Overload Transferring with interruption UPS Fault Input Voltage Input Frequency Output Voltage Output Frequency Loa...

Page 25: ...k energy com France and Benelux fbnl alpha outback energy com Spain spain alpha outback energy com Russia russia alpha outback energy com Africa africa alpha outback energy com Alpha and Outback Energ...

Reviews: