background image

UPS  fails 

to offer 

battery backup 

or  its backup 

power time  is 

shorter than 

calculated. 

If  the  backup  power  time  is  still  too 

short after  8  hours  of  charging  please 

contact your 

local 

distributor 

for 

battery replacement. 

UPS

 

locks

 

itself 

and  can  not 

be  turned off. 

5. Communication Software

5.1.  Hardware Setup 

1. Connect the male connector of the USB cable to the UPS communication

port.

2. Connect the female connector of the USB cable to a dedicated USB port of

the attached computer.

3. For optional interface cards refer to Chapter 6 for installation.

5.2.  Software Installation 

Please refer to the software user’s manual. 

Page 

3

9

 to 

4

5

Page 

3

8

 to 

4

5

6. Optional Interface Cards

6.1. 

DCE (Dry Contact)-B card

Refer  to  section  3.5.6  to  troubleshoot 

the problem;  otherwise,  consult  your 

local distributor for help. 

Situation 

Check Items 

Solution 

Pin 1: UPS on Bypass mode 

Pin 2: Utility Abnormal 

Pin 3: Utility Normal 

Pin 4: Inverter On 

Pin 5: Battery Low 

Pin 6: Battery Bad or Abnormal 

Pin 7: UPS Alarm 

Pin 8: Common 

Pin 9: Shutdown UPS positive (+) signal   

Pin 10: Shutdown UPS negative (-) signal 

6.

1

.1.  pin assignments of 10-pin terminal: 

1  2  3  4  5  6  7  8  9  10 

6.

1

.2.  The shutdown function will be activated after +6~+25 VDC is applied 

between pin 9 and pin 10 for 5 seconds. 

6.

1

.3.  The capacity of each relay contact is 40 VDC/25mA. 

6.

1

.4.  Installation Position: slot 1 (CHA-CN7) or slot 2 (CHB-CN8) 

6.

1

.5.  Flexible signal output for N.C. (Normal close) or N.O. (Normal open) 

contact by shorting pins 1-2 or pins 2-3 from JP1-5 

6.

1

.6.  The shutdown function will be enabled 1 minute after blackout occurs if 

pins 1-2 of both CN1 and CN6 are shorted. Otherwise the shutdown 

function can be enabled only by pins 9-10 of CN3 if pins 2-3 of both 

CN1 and CN6 are shorted. (Refer to 

6.

1

.2.

Summary of Contents for Continuity 10K

Page 1: ...Continuity 6K 10K USER MANUAL...

Page 2: ...5 3 Installation and Operation 16 3 1 Unpacking 16 3 2 Selecting Installation Position 17 3 3 Installation of Accessories Kit 18 3 4 Terminal Block Explanation 19 3 5 Installation and Operation 23 4 T...

Page 3: ...ondensing humidity 1 1 11 Do not install the UPS in direct sunlight Your warranty may be void if the batteries fail 1 1 12 Install the UPS indoors as it is not designed for installation outdoors 1 1 1...

Page 4: ...parts on top of batteries 5 Disconnect charging source prior to connecting or disconnecting battery terminals 6 Determine if battery is inadvertently grounded If inadvertently grounded remove source f...

Page 5: ...pass mode and vice versa 2 1 7 The fully digitalized control circuit built into the UPS allows upgrading the functionality of the UPS as well as reaching a high level of protection of the UPS Powerful...

Page 6: ...ry charging device k Internal Battery When AC abnormal it provide the backup power from the batteries l External Battery Bank To provide longer backup time by adding additional Battery bank m Inverter...

Page 7: ...hort Circuit 27 Er10 Inverter Over current Item Symbol Description 28 Er11 The UPS is overheated 29 Er12 UPS Output Overloading 30 Er14 Fan Error 31 Er15 Wrong Procedure to Enter Maintenance Mode 32 E...

Page 8: ...ndicates that the utility input voltage is outside the acceptable window Green LED indicates that Bypass Input is normal UPS ON Alarm Silence Go to previous page or change the setting of the UPS Confi...

Page 9: ...1 1 You may use optional interfaces cards for R2E RS 232 RSE RS 485 USE second USB DCE Dry Contact and SNMP However the R2E card RSE card and USE card must not be used simultaneously 2 4 1 2 The softw...

Page 10: ...y but not for moving UPS 3 2 Selecting Installation Position Install the UPS in a proper environment to minimize the possibility of damage to the UPS and to extend the life of the UPS Please follow th...

Page 11: ...e terminals for UPS Output G2 the terminal for UPS Output Ground Remarks 1 The maximum current for each terminal is 36 Arms for 6 kVA 65 Arms for 10 kVA 2 If the UPS is a SIM Single Input type only AC...

Page 12: ...module socket 3 Please refer to the specifications of input current output current and recommended conductors listed below a AC input and output minimum 75 C copper wire b Battery input Page 21 to 45...

Page 13: ...sure the utility voltage matches the input voltage window of the UPS 3 5 1 4 Connect the utility separately to the terminal blocks of the UPS Utility and Bypass inputs Switch on the power breaker of t...

Page 14: ...or error status will appear on the screen 3 5 1 9 Your start up operation of the UPS is complete now Make sure the UPS is plugged into the wall receptacle for charging at least 8 hours and the batteri...

Page 15: ...own the LCD will display figure C Voltage from Utility Input figure I1 Voltage from Bypass Input figure J Frequency from Utility Input figure K Frequency from Bypass Input figure L UPS Output Voltage...

Page 16: ...UPS battery numbers Page 29 to 45 Page 28 to 45 P UPS inner temperature 3 5 4 UPS Default Data and Special Function Execution 3 5 4 1 After the UPS completely starts up press the key to change the LC...

Page 17: ...r Output Voltage figure V1 UPS Operation Mode figure W Output Voltage Micro Tune Value figure X UPS Id figure Y Parallel function status R1 Self test is not On R2 Self test is On S1 Bypass Voltage is...

Page 18: ...in setting mode 3 5 5 2 To scroll through the options refer to section 3 5 4 2 3 5 5 3 Except for Buzzer figures Q1 and Q2 and Self test figures R1 and R2 all of the other default settings may be chan...

Page 19: ...d twice 3 5 6 2 4 Turn Off the Utility Input breaker 3 5 6 2 5 Even if the UPS lock problem is solved now consult with your local distributor to make sure that the error condition is resolved 3 5 7 Sh...

Page 20: ...36 to 45 Situation Check Items Solution red Fault LED Check the error code shown on the LCD 1 Check for proper battery connection then recharge the batteries for 8 hours to see whether the UPS provid...

Page 21: ...lt your local distributor for help Situation Check Items Solution Pin 1 UPS on Bypass mode Pin 2 Utility Abnormal Pin 3 Utility Normal Pin 4 Inverter On Pin 5 Battery Low Pin 6 Battery Bad or Abnormal...

Page 22: ...6 2 DCE Dry Contact C card 6 2 1 Please refer to the New Dry Contact Card English Installation Guide A5 192321002014002 Page 41 to 45 Page 40 to 45 6 3 Interface Card Installation...

Page 23: ...ly Battery Low Battery Bad Disconnect Overload Transferring with interruption UPS Fault Input Voltage Input Frequency Output Voltage Output Frequency Load Percentage Battery Voltage Inner Temperature...

Page 24: ...LCD Line Mode Backup Mode ECO Mode Bypass Supply Battery Low Battery Bad Disconnect Overload Transferring with interruption UPS Fault Input Voltage Input Frequency Output Voltage Output Frequency Loa...

Page 25: ...k energy com France and Benelux fbnl alpha outback energy com Spain spain alpha outback energy com Russia russia alpha outback energy com Africa africa alpha outback energy com Alpha and Outback Energ...

Reviews: