background image

24

RDM Protocols

(3/3)

Table 1.

Model

Value

Description

4 Ch. Model Device

(Variable Color Temperature & RGB)

2 Ch. Mode

2 Ch. Mode (Dimming / Color Macro)

6 Ch. Mode

6 Ch. Mode (Red / Green / Blue / Amber / Royal Blue / White)

7 Ch. Mode

7 Ch. Mode (Dimming / Red / Green / Blue / Amber / Royal Blue / White)

9 Ch. Mode

9 Ch. Mode (Dimming / Red / Green / Blue / Amber / Royal Blue / White / Color Macro / Strobe)

Error Message

No.

Condition

Level

Description

Display

1

Sensor Over Temp

Warning

Fixture temperature 46 ~ 69˚C

Orange message

2

Sensor Over Temp

Error

Fixture temperature over 70˚C

Red message

Sensor

No.

Device Sensors

Value (Example)

Description

User Setting

Remarks

1

Sensor Temp

64 ˚C

Current fixture temperature

Disable

Summary of Contents for CYC 500H

Page 1: ...LED LIGHTING FOR UHD BROADCASTING EST 2008 USER MANUAL CYC HORI LIGHT CYC 500H 6CH ...

Page 2: ...y chain on the product when installing and moving 4 Please install the signs below for people to bypass when install the product on high truss 5 The work should be done under the direction of approved specialist who is trained in safety and mechanical installations 6 The brightness and color temperature before and after aging may be different Safety Information WARNING ...

Page 3: ...y Mode Product Information 12 DMX Mode Channel Change Address Setup 13 User Mode Intensity ColorTemperatureAdjust 14 Color Mode RGB Hue Saturation White Adjust 15 Extra Function Sleep Mode Function 16 Master Function 16 RDM Function 16 Dimming Speed Setup 16 Fixture ID Number Setup 17 Fixture Label Setup 17 Error Information Temperature Sensor 18 Network Connection 18 Extra Information Color Macro...

Page 4: ...ation and DMX signal check and error message can be checked Smart touch control method makes it easy and convenient to check all information at a glance Operate Hue Saturation function for color direction by using Smart Touch Screen The console function can be temporarily replaced through the MASTER SLAVE function When the DMX signal is shorted the last signal is maintained Long life reduce mainte...

Page 5: ...4 Fixture Exterior View Smart Touch LCD Screen Connector Panel Fixed Knob ...

Page 6: ...5 Dimensions mm inch ...

Page 7: ...sumption 300W Colored Light Full RGB Amber White Royal Blue White Light CCT 3 000 10 000K VCT in Color Macro CRI 80 94 Dimming 0 100 16 bit CCT Deviation 100K Control 5 PIN DMX In and Out Smart Touch LCD Controller RDM Option Wireless DMX512 Wireless RDM Remote Device Management Supported Ambient Temperature Operation 20 45 C IP Rating IP20 Estimated LED Lifetime Over 50 000 hours This specificati...

Page 8: ... be generated from the SMPS 3 If the operating voltage is out of the proper voltage range SMPS function may be degraded or damaged AC power at 100 240V 50 60Hz 1 POWER ON OFF SWITCH 2 POWER IN 3 POWER OUT 4 DMX IN 5 DMX OUT 6 USB PORT forFirmwareUpdate Do not connect USB without administrator s permission ...

Page 9: ...er lighting fixture If user uses a standard DMX controller the DMX output of the controller can connect directly to the DMX input of the first fixture in the DMX chain User must use an adapter cable for connect the DMX controller to other XLR output Connect the DMX output of the first lighitng fixture in DMX chain to the DMX input of the next fixture and connect one output to the input of the next...

Page 10: ...Locked Fixture ID Screen Locked When the fixture is turned on the Smart Touch screen automatically locked To unlock the touch screen touch the finger icon three times If you do not touch for 30 seconds the lock is reset A A A ...

Page 11: ...ure and Tint 8 Home Return to the main screen 9 DMX512 Mode Address Setup Set channel mode and DMX512 address 10 User Mode Setup Set Intensity and CCT manually 11 Color Mode Setup Set RGB lighting color Saturation and Intensity 12 Setting Setting or changing the function of the equipment 13 Fixture ID Displays numbers for equipment management 14 Equipment Information Displays the help that describ...

Page 12: ...mation Description of fixture ID Θ Information Basic equipment information Θ Rotate Θ Home Main screen Θ DMX512 Mode DMX mode select DMX address input Θ Information DMX channel value Θ User Mode Intensity setup Color temperature setup Θ Information Description of each function Θ Color Mode RGB color setup Saturation setup White setup Θ Full screen Individual RGB setup and Preset Θ Information RGBW...

Page 13: ...and fixture temperature are displayed and some lighting value can be adjusted on the main screen by touching the value User can check information such as manufacturer product model name firmware version UID number current temperature of equipment usage time of equipment LED usage time website manual download link etc by clicking the INFO button on the main screen Through each Menu INFO touch user ...

Page 14: ...etup Pressing the Info button in DMX512 MODE displays each channel information and value To return to the previous screen press the Info button again Support channels and features vary by product User can move to the DMX channel change screen by selecting DMX512 MODE button in main screen In DMX512 MODE screen user can select DMX channel mode on top tap and input DMX512 address by pressing the num...

Page 15: ...nt to change to activate Orange color and can adjust the activated value by dragging Drag the activated bar close to the desired value and then touch to set the exact value Intensity The number indicates the current brightness value of the fixture and is displayed from 0 to 100 CCT The number indicates the current color temperature value of the fixture and is displayed from 2 900 to 6 000K Pressin...

Page 16: ...the up down left and right arrows After adjusting the desired value press Enter to return to the COLOR MODE screen Color Mode It is used when the user directly manipulates the equipment Color Wheel Gradient Touch or drag the color user want Hue Drag and select the Hue user want Saturation The number indicates the current saturation value of the fixture and is displayed from 0 to 100 White The numb...

Page 17: ...tures without a console connection If Off the DMX signal will follow RDM setup Default On Set the feature that enables bi directional wireless communication through RDM equipment If Off this equipment will not be searched on RDM equipment Dimming speed setup The number indicates the current dimming speed value of the fixture and is displayed from 0 to 40 The higher the value the slower the dimming...

Page 18: ...vice is basically the model name and it can be changed through RDM communication but it can t be changed through the Smart Touch LCD When changing the label of the device through RDM enter the device name English and the management number in the Device Label field The entered contents are displayed in the upper left corner The fixture ID is automatically displayed in 3 or 4 digits from automatical...

Page 19: ...LED output will be 0 and Temperature Error Please Check Device will be displayed The error messages are only displayed on the main screen and the fixture ID screen Even if the temperature falls to the normal range It does not disappear In this case normalize the temperature of the equipment and restart it Temperature Sensor When the DMX512 network connection is lost the DMX512 address number in ma...

Page 20: ...19 Color Macro Light Distribution Channel 4 is Color Macro express rainbow gradation effect The order is Red Green Blue 6m w x 8m h 12m w x 8m h Color Macro Distribution ...

Page 21: ...100 Amber 5 0 255 0 100 Royal Blue 6 0 255 0 100 White 7 1 0 255 0 100 Dimming 2 0 255 0 100 Red 3 0 255 0 100 Green 4 0 255 0 100 Blue 5 0 255 0 100 Amber 6 0 255 0 100 Royal Blue 7 0 255 0 100 White 9 1 0 255 0 100 Dimming 2 0 255 0 100 Red 3 0 255 0 100 Green 4 0 255 0 100 Blue 5 0 255 0 100 Amber 6 0 255 0 100 Royal Blue 7 0 255 0 100 White 8 0 255 Color Macro 9 0 255 Strobe ...

Page 22: ...5 78 79 82 83 86 87 90 91 94 DMXValue ColorValue ColorMacro 179 182 183 186 187 190 191 194 195 198 199 202 203 206 207 210 211 214 215 218 219 222 223 226 227 230 231 234 235 238 239 242 243 246 247 250 251 255 DMXValue ColorValue ColorMacro 95 98 99 102 103 106 107 110 111 114 115 118 119 122 123 126 127 130 131 134 135 138 139 142 143 146 147 150 151 154 155 158 159 162 163 166 167 170 171 174 ...

Page 23: ...L YES YES SENSOR_DEFINITION YES SENSOR_VALUE YES DMX_PERSONALITY YES YES DMX_PERSONALITY_DESCRIPTION YES STATUS_MESSAGES YES Lamp Controls No Control Property Value Example Description UserSettings Remarks 1 Identify On N A Device identification action active Enable Identify device Same as On 2 Identify Off N A Device identification action inactive Enable Identify device Same as Off 3 Cold Reset N...

Page 24: ...Start Address 1 DMX address Enable 1 512 Range 7 Device Hours N A N A Display only no actual response 8 Lamp Hours N A N A Display only no actual response 9 Lamp State N A N A Display only no actual response 10 Lamp On Mode N A N A Display only no actual response 11 Display Invert On LCD screen display direction Enable Off 0 On 180 Auto Current opposite direction 12 Identify Device Off Selected fi...

Page 25: ...reen Blue Amber Royal Blue White 9 Ch Mode 9 Ch Mode Dimming Red Green Blue Amber Royal Blue White Color Macro Strobe Error Message No Condition Level Description Display 1 Sensor Over Temp Warning Fixture temperature 46 69 C Orange message 2 Sensor Over Temp Error Fixture temperature over 70 C Red message Sensor No Device Sensors Value Example Description User Setting Remarks 1 Sensor Temp 64 C C...

Page 26: ......

Reviews: