background image

ICON DISPLAY AREA

The heating wire starts the heating icon to light up, and the heating wire 
closes the icon to hide.

Fan start fan icon lights up and rotates, fan stop icon is hidden.

A t   t h e   s a m e   t i m e ,   p r e s s   t h e  
(MENU+ADD) child lock function to 
open  (the  icon  is  lit).  Pressing  any 
button  at  this  time  will  not  change 
the  setting  of  the  current  screen. 
When  the  buttons  are  misoperated 
for  2  or  more  times  in  a  row,  the 
child  lock  small  pop-up  window 
pops  out  (as  shown  below).  If  you 
need  to  change  the  setting,  you 
need to exit the lock mode and press and hold (MENU+ADD) for more 
than three seconds to close the child lock mode.

The machine has been locked, and 
long press “MENU+ADD” to exit, th
enother keys can be operated.

MENU

LESS

ADD

TEMPERATURE DISPLAY AREA

In Temp: is collected in the temperature probe at the air inlet  Controller Temp is 
collected in the temperature probe at the remote control.

When the remote control is not connected, the font "IN TEMP" turns yellow. The 
thermometer symbol of the same color is displayed in front of the font, and the 
temperature  value  "SET  TEMP"  is  adopted  by  "IN  TEMP". When  the  remote 
control  is  connected  to  the  device,  the  "IN  TEMP"  turns  white  and  the 
thermometer  symbol  disappears.  (  the  air  inlet  temperature  probe  ends  the 
work  of  the  heating  wire  as  long  as  the  detected  temperature  exceeds  122 

degrees Fahrenheit (50 

) in any mode. )

In Temp

Electric Heat Drying System

08

Summary of Contents for MAX Fire Dry 200

Page 1: ...ions INC Add 2048 E Francis St Ontario CA 91761 Tel 888 990 7469 E mail sales alorair com MAX Fire Dry 200 Portable Heater OWNER S MANUAL Electric Heat Drying System Specifications subject to change w...

Page 2: ......

Page 3: ...ckets with grounding We standard equipped with 4 14AWG length 25 feet power cord for you if you need a longer power cord you can buy 50 feet power cord from the dealer or designated network Check whet...

Page 4: ...Matters needing attention overview Accessories and maintenance Service section LCD display instructions Wiring diagram Troubleshooting Warranty and after sale Electric Heat Drying System 01 02 04 06 0...

Page 5: ...ed to the correct socket with grounding In order to prevent possible fire do not block the air inlet or exhaust in any way Do not use on soft surfaces such as beds where openings may be blocked Use th...

Page 6: ...mum heat 20000 Btu Maximum setting temperature 122 Air volume 250 CFM Filter MERV 8 Pipeline Import and export 8 inch flexible pipe aluminum conduit Width 12 6 17 Height 12 6 17 8 Depth 26 2 30 5 Weig...

Page 7: ...ata cable to the EXTERNAL CONTROL GONNECTOR socket to switch on the controller for external temperature detection and control as shown in figure When the equipment is not in use please shut down the o...

Page 8: ...8 7 x 0 6 in MERV 8 1 x 24 6 feet long 4 x 24 6 feet long 1 2 EXTERNAL PIPE Max Fire Dry 200s can be connected to the inlet outlet or both to accommodate 8 flexible pipes When choosing flexible pipes...

Page 9: ...the filter you can usually clean it once with a vacuum cleaner Replacement filters can be ordered from the factory or purchased locally if any Warning do not operate this machine without a filter or...

Page 10: ...mber Specification Foot Pad Main Switch External Controller Socket Display Screen MERV 8 Filter Net Indicator Light Socket Overload Switch Number 1 3 2 4 5 6 7 8 8 1 1 1 1 1 4 3 1 2 3 4 5 6 7 8 Electr...

Page 11: ...DD button increase the number each time you press LESS button reduce parameters each time you press MAIN INTERFACE FUNCTION The temperature setting range is between 32 F 120 F 0 C 50 C each button ADD...

Page 12: ...to close the child lock mode The machine has been locked and long press MENU ADD to exit th enother keys can be operated MENU LESS ADD TEMPERATURE DISPLAY AREA In Temp is collected in the temperature...

Page 13: ...rol is inserted but the temperature data cannot be collected the small pop up window for the failure of the remote control probe pops up The set temperature value SET TEMP will be valid for IN TEMP Co...

Page 14: ...enter the page the number returns to 00 00 3 Standby time setting press the menu button to enter the standby time setting page press add and less to adjust the parameters and confirm that the set par...

Page 15: ...the device are activated and turned on at the same time until the set time is finished and then enter the cycle GENERAL SETTING Page order home page temperature unit setting interface temperature sett...

Page 16: ...Ndicator Light 1 Overload Protection Switch 1 White Overload Protection Switch 3 Black Black Red Red Red Black Black Temperature Switch Thermal Protector 2 Ptc Resistance Wire 2 1500w Ndicator Light 2...

Page 17: ...e sure the remote control cable is connected at both ends and contact customer service if there is no problem Remote control probe failure small pop up window Ma2 Rt1 Power Outage Reset power Thermal...

Page 18: ...ustomers are not available 2 After the unit has been received by AlorAir whether at a repair center or the warehouse AlorAir will have an initial inspection lf it is determined to be invalid warranty...

Page 19: ...Electric Heat Drying System WARRANTY 15...

Page 20: ......

Reviews: