7.  WARRANTY & SERVICE EXCHANGE

 

Almeco warrants all products manufactured by ACI to be free of defects in material and workmanship for eighteen (18) 

 

months from the date of shipment. The warranty does not apply to drive belts, filter elements or connecting hose, unless 

 

authorised by an officer of ACI. Also, not covered under the warranty is normal wear and tear, neglect or misuse of the 

 

equipment, operation in an application not approved by Almeco and ACI, and alterations not performed by Almeco.

 

All items supplied by Almeco that are manufactured by others shall be warranted under the respective manufacturer’s 

 

policy. Motors and other items, for which a national service network is in place, should be sent directly to that 

 

manufacturer’s representative for the most prompt service. Almeco will provide any support required ensuring that 

 

warranty service by others is handled in a prompt and professional manner.

 

The Almeco warranty is limited to the repair or replacement of items shipped by Almeco. At no time will Almeco be liable  

 

for any of the costs to the buyer for labour, transportation or down-time resulting from defective equipment furnished by  

 

ACI, Almeco or our suppliers.

 

To comply with the Warranty the complete fan unit must be returned to Almeco. Disassembly of the fan will invalidate the

 warranty.

 

Service Address:

 

Our products are manufactured in compliance with applicable international standards and regulations. If you have any 

 

queries regarding the use of our products, or if you are planning a special application, please contact:

ALMECO nv 

Air and water technologies

Royennestraat 51, B-7700 Moeskroen

[email protected] - www.almeco.eu

Summary of Contents for ACI EP10A

Page 1: ...www almeco eu DRYING SYSTEMS EP10A Compact blower Installation operation maintenance Instruction manual EP10A compact blower...

Page 2: ...information 4 a Description and model identification b Equipment arrival 3 Key features and dimensions 5 a Key EP10A features b Key EP10AH features c Illustration further EP10A key features 4 Install...

Page 3: ...of starts and stops if so then use a timer delay in the control to avoid frequent switching The EP10A blower needs to have airflow passing through it to ensure temperatures are not exceeded The use of...

Page 4: ...or as a hot air version EP10AH where air temperatures of up to 365 F 185 C can be processed Almeco clearly labels each EP10A EP10AH blower unit on the back of the blower head as well as the motor cow...

Page 5: ...er should be cleaned regularly and the main element replaced every six months Drive belt guard Poly V belt Motor pulley Motor IE3 Blowerhead EP10 A Filter Ref B3 003 039 B3 000 185 Pre lter B3 000 147...

Page 6: ...www almeco eu Ref B3 003 037 Thermal cut Hot air Ref ACEP 250H 7 EP10A compact blower c Illustration furtherEP10AKeyFeatures d EP10AHeadOptions Electric Motor Standard Metric or NEMA Filter Assembly B...

Page 7: ...mounting plate is provided to suit the large C face configuration NOTE Allow room for bracket movement during belt replacement Very low vibration levels of these units allow them to be bolted to any...

Page 8: ...r If an inverter is not used use a suitable starter with overload protection star delta starter f Shaft rotation All units rotate counter clockwise when viewing the blower from the cooling fan of the...

Page 9: ...tend the life of the mechanical components and ensure continued efficiency and longevity Removing filter element Step 1 Remove pre filter element by releasing the security nut and washer Use a 17mm AF...

Page 10: ...f the unit is still not dry Re fitting filter elements Once the main filter element and the pre filter sock are thoroughly dried they can be re fitted to each other Refit the filter and its cover and...

Page 11: ...2 nuts on the adjusting screw apply sufficient tension to raise the blower head back plate assembly into its approximate position and lightly tighten the M10 bolts to hold the assembly in place Tensio...

Page 12: ...ith the poly vee pulleys Do not force the belt or roll the belt onto the pulleys Ensure the blower head is low enough to allow the belt to clear before attempting to fit Using the M12 nuts on the adju...

Page 13: ...lter Maintenance Damaged hose lining Replace damaged hose Air leaks in system Check replace damaged hose and clips Drive belt slipping Worn Pulley Replace transmission parts Incorrect speed from contr...

Page 14: ...cal overloading Exceeding rated CFM Reduce open area of air delivery devices i e slot width of Airknives Blower not piped to system Only run blower when connected to the operating system Never run in...

Page 15: ...espective manufacturer s policy Motors and other items for which a national service network is in place should be sent directly to that manufacturer s representative for the most prompt service Almeco...

Reviews: