10x Installation Guide
4 Mechanical
4.1 Tabletop or Shelf Placement
To install the Allworx 10x on a tabletop or shelf:
1. Remove the four rubber feet from the Accessory Kit.
2. Turn over the chassis and notice the circles on each corner.
3. Remove the paper backing from each rubber foot and place one foot in each circle.
4.2 Rack Mount
To install the Allworx 10x in a standard 19-inch equipment rack:
1. Remove the two brackets and associated screws from the Accessory Kit.
2. Place the brackets so that the smaller faces extend away from the front of the unit as shown in Figure 3.
Figure 3: Rack Mount Bracket Installation
3. Install the mounting brackets on each side of the chassis using four 8-32 flat head screws.
4. Perform the electrical installation as shown in the instructions below before placing the chassis into the
rack.
4.3 Wall Mount
To mount the Allworx 10x on a wall:
1. Verify that there is sufficient clearance around the server’s front and rear panels to allow power, network,
and telephony connections.
2. Remove the two brackets and associated screws from the Accessory Kit.