http://www.alltraxinc.com
Controller Amperage
F/R Size
400A or less
Stock/HD
450A to 650A
Heavy Duty/Change-Over
Contactor
650A or more
Change-Over Contactor
The forward/reverse switch is an often overlooked part of the
upgrade process. In a series motor, all of the motor current will
pass through the F/R switch. An undersized F/R Switch is as bad as
an undersized solenoid or small wire gauge.
For higher amperage controllers (>600A), it is suggested that a
change-over contactor set up be used. These are large enough to
handle the higher currents without over heating the contacts and
they provide the user the ability to change direction by flipping a
switch.
F/R Switch
Change-over contactors are multiple contactors bound together
that allow the user to change the polarity of the voltage going to
the motor thus reversing direction. It works exactly the same as the
manual F/R switch, except that it uses coil drive contactors. See the
installation drawings for how to wire up a change-over contactor.
Summary of Contents for SR48300
Page 15: ...15 http www alltraxinc com PRE 1994 EZGO...
Page 16: ...16 SR OPERATORS MANUAL 1994 AND NEWER EZGO...
Page 17: ...17 http www alltraxinc com 1994 AND NEWER CLUB CAR...
Page 18: ...18 SR OPERATORS MANUAL YAMAHA G8 G9 G14 G16...
Page 19: ...19 http www alltraxinc com TAYLOR DUNN GENERIC WIRING...
Page 20: ...20 SR OPERATORS MANUAL GENERIC SERIES WITH REVERSE...
Page 21: ...21 http www alltraxinc com GENERIC SERIES W O REVERSE...
Page 22: ...22 SR OPERATORS MANUAL Generic Series w SW202 Reverse...
Page 23: ...23 http www alltraxinc com Generic Permanent Magnet...
Page 24: ...24 SR OPERATORS MANUAL Permanent Magnet no Reverse...
Page 32: ...DOC113 014 E_OP SR Operators Manual doc ALLTRAX INC 2016 All Rights Reserved...