8
SR OPERATORS MANUAL
The resistor typically seen across the contactors big terminals
pre-charges the filter capacitors in the controller. This minimizes
arcing across the
contactor terminals
when closing.
INSTALLATION
Battery Voltage
Resistor
12-36V
220-250 Ohm 10W
48V
470 Ohm 10W
72V
1000 Ohm 10W
Diode
Resistor
Resistor & Diode
Mounting
Contactor Size
Diode
Diode Current
70A-200A Solenoid
1N4004
1A
400A-550A Solenoid
1N5408
3A
600A or larger Solenoid
MR754
6A
The diode across the coil terminals safely dissipates the energy
when the coil is turned off. Installation Dependant, refer to