User guide
3
•
Success of sensor warming up
- оne long beep per second
•
Sensor fault
- long beep once per second until sensor is re-
covered from fault
•
Device self test
- three short beeps twice per second
•
Mild gas leak
- long beep once per second, until gas leakage
is not present or if switching to “Heavy gas leak” mode
•
Heavy gas leak
- The device beeps for five seconds with one
second pause until gas leakage is not present
•
Successful self test
- long beep once per second
Installation Instructions
!CAUTION -
Before beginning the installation please read the
accompanying documentation carefully and completely. Failure
to follow recommended procedures could lead to malfunction,
danger to your life or violation of the law. Allterco Robotics is
not responsible for any loss or damage in case of incorrect in-
stallation or operation of this device.
!CAUTION -
Use the Device only with power grid which com-
plies with all applicable regulations. Short circuit in the power
grid may damage it.
!CAUTION -
Do not allow children to play with the device, espe-
cially with the Power Button. Keep the devices for remote con-
trol of Shelly (mobile phones, tablets, PCs) away from children.
Initial Inclusion
Place Shelly into the power socket, in the room where you want
to use it.
•
For
CNG
gas detection the Shelly Gas CNG unit is best to be
placed 0.3~1m below ceiling vertically and 1.5m away from the
natural gas source.
•
For
LPG
gas detection the Shelly Gas LPG unit is best to be
placed 0.3m above floor, and within 1.5m from gas source.