Machine:
Before storage, wash the complete machine, then grease or oil all
weekly lubrication points as above. Open the drain bung in the
mixing chamber. Check tyre pressures. Store the machine under
cover or under a tarpaulin, if possible.
Electronic weigh box:
If the machine is to be stored, remove the Weigh Box unit from the
machine and keep in a dry place. Lightly grease the load cell cable
connector end and place into a plastic bag.
Wheels:
Remove and inspect wheel hub. Replace worn parts, redress and
re-fit.
Blades:
Blades need to be kept sharpened. This will have to be done
without taking the temper (over heating) from the blades. If the
machine is operated with blunt blades it will cause major stress on
the drive system. Blades may have to be replaced when it is not
practical to sharpen them.
10 Specification
10.1 Weight
Table 8 : Machine weights
Note:
Weights may vary depending on exact specifications.
* The pre-mix or caustic soda capacity is 8000 kgs/17600 lbs, due to its nature in weight and density.
Further advisements can be found in sections 7.3: Diet feeder capacity and 7.4: Loading and mixing.
WARNING:
Due to the hazards of entering the mixing chamber, it is recommended that all blade
replacement is carried out by a KEENAN-authorized service agent who is specially
trained to do this. Contact your local agent (see back cover for details).
Model Weight
MechFiber400
With bale handler
Unladen
kgs
13,750
14,750
lbs
30,313
32,518
Payload
kgs
10,000*
lbs
20,046*
Gross
kgs
23,750
24,750
lbs
52,359
54,564