background image

5

Product description

6-1622410 Rev.1 01/10/2019

Product description

General product overview

10

9

12

20

3

7

16

1

16

8

13

11

17

4

*

7

8

 

* Example garage door illustration

1.  Drive head including LED module

11.  Door connector attachment

3.  Rail (model example) drive side

12.  Linking bar

4. Carriage

13.  Central support

7.  Rail connector (model example)

16.  Support straps drive head

8.  Rail (model example) door side

16.  Support straps track

9. Tensioner

17.  Mains cable, 1.2 m

10.  Wall bracket

20.  Telescopic fitting for sectional doors (accessory)

Control elements

A

C

B

A1

D

15

1

A.  Numerical display (A1 digital point)

B.  OPEN / Start button

C.  CLOSE button

D.  Program button (PROG button)

 

1.  Drive head

15. Hand transmitter (TECH3 PLUS)

Summary of Contents for SEKTIO 500

Page 1: ...SEKTIO 500 6 1622410 REV 1 OPERATOR 24Vdc FOR SECTIONAL AND GARAGE DOORS ...

Page 2: ...wer and controls 9 Routing the antenna 11 Program the drive head 12 Special settings 15 Complete the installation procedure 18 Operation 19 Safety instructions for operation 19 Open or close the garage door in normal operation mode 19 Manually open or close the garage door 20 Open or close the garage door other operation modes 20 Diagnostic display 21 Restore the factory settings 22 Cycle counter ...

Page 3: ...guage version is a translation of this original Symbols used in this manual Warning This indicates a possibly dangerous situation that might lead to serious injury Warning high voltage This indicates work steps that may be carried out only by a trained and skilled electrician Caution This indicates a possibly dangerous situation that might lead to material damage to the product Use according to pu...

Page 4: ...ration 4 Please also see the safety instructions for operation see on page 18 5 Installation must only be carried out about by qualified technicians Specific safety precautions 6 The product runs on high voltage Before you start work on electrical systems do the following 1 Make sure that the product is disconnected from the electrical power supply 2 Make sure that the power cannot be reconnected ...

Page 5: ...e drive side 12 Linking bar 4 Carriage 13 Central support 7 Rail connector model example 16 Support straps drive head 8 Rail model example door side 16 Support straps track 9 Tensioner 17 Mains cable 1 2 m 10 Wall bracket 20 Telescopic fitting for sectional doors accessory Control elements A C B A1 D 15 1 A Numerical display A1 digital point B OPEN Start button C CLOSE button D Program button PROG...

Page 6: ...f the opening garage door encounters an obstruction the door stops and moves back for approximately 1 second Installation Drive and accessories 2x AWG 22 2x AWG 22 2x AWG 22 2x AWG 22 m m 0 0 5 1 m m 0 0 8 1 x a m IRIS PULS IRIS PULS BAT IRIS PULS IRIS PULS BAT Safety instructions for installation Installation must only be carried out about by qualified technicians Read these installation instruct...

Page 7: ...il connector model example 8 Rail model example door side 9 Tensioner 10 Wall bracket 11 Door connector attachment 12 Linking bar 13 Central support 14 Bag of screws 15 Handheld transmitter TECH3 PLUS 16 Ceiling mounting 17 Mains cable 1 2 m length 18 Mounting bracket 19 Warning label Optional Attention Check the supplied screws and wall plugs to make sure that they are suitable for the structural...

Page 8: ...uspension 13 to the guide rail Mount the mounting brackets 18 on the drive head 1 4 Mount the connector attachment 11 to the garage door 5 Mount the wall bracket 10 6a 6c d Mount the guide rail 3 8 to the wall bracket 10 Mount the ceiling mountings 16 to the center bracket 13 and to the drive head 1 Then mount the ceiling mountings 16 to the ceiling 7 Connect the linking bar 12 between the carriag...

Page 9: ...that it is working properly and safely see section on Maintenance Checks Warning Danger by optical radiation If you look at an LED for an extended period from a short distance this can cause optical binding Sight is then severely restricted for a short time This can result in serious or fatal injuries You must not look directly at an LED H G F E 1 External antenna Lead the antenna upward through t...

Page 10: ...or For further information on our range of accessories please refer to our sales literature or consult your specialist dealer Warning Following the connection of 2 wire pulsed photocells IRIS PULS or IRIS PULS BAT it is necessary to repeat the learning sequence of learning of the end positions including the force learning cycle Warning label WARNUNG Automatisches Tor Nicht im Bewegungsbereich des ...

Page 11: ...1 Open the cover at the drive head 2 Use a suitable tool e g a screwdriver to break out the material at the predetermined breaking point for the feed through and insert the supplied cable sleeve into the resulting opening 3 Take the antenna out of the transport lock and feed it outwards through the feed through 4 Close the cover at the drive head Note When using an external antenna the shield must...

Page 12: ...play flashes press the hand transmitter button with which you will later start the drive until the digital point A1 on the display blinks 4 times 3 As soon as the light goes out you can set the next hand transmitter see Step 1 Note Up to 10 codes can be learned D C B A1 Menu 2 Programming the 4 minute light 1 Briefly press the programming button PROG button D twice The display shows 2 2 Press the ...

Page 13: ...ition CLOSE If needed press the OPEN button A to adjust the position 8 Once the garage door is at the desired end position CLOSE press the programming button PROG button D The display shows 0 9 Continue with the force learning cycle B C D Force learning cycle Warning During this procedure the operator automatically learns the normal mechanical force required to open and close the garage door Force...

Page 14: ...ues are not complied with the force limit needs to be set according to the section Menu 5 Menu 6 Force limitation for Open and Close on page 15 Delete force learning cycle Note The force learning cycle always starts from the end position CLOSE The force learning cycle must be repeated after each replacement of the garage door springs Proceed to Menu 5 see special settings and keep the programming ...

Page 15: ...t for closure appears 4 If desired adjust the setting with the aid of the OPEN B and CLOSE C buttons Warning The force on the main closure side must not exceed 400 N 750 ms 5 Press the programming button PROG button D The display shows 7 Menu 7 Adjust the light phases 1 Select menu item 7 After about 2 seconds the display blinks and the set value for light time appears The factory setting is 0 2 I...

Page 16: ...ly with the express permission of the door manufacturer 2 If desired adjust the setting with the aid of the OPEN B and CLOSE C buttons Menu value Start OPEN Stop OPEN Start CLOSE Stop CLOSE 0 0 0 0 0 1 15 0 15 0 2 0 15 0 40 3 15 15 15 35 4 15 15 15 60 5 25 30 20 35 6 15 15 15 20 7 15 15 65 45 8 55 15 15 100 9 only soft run Remarks These values correspond to the soft run courses measured on carriag...

Page 17: ...press the second button on the hand transmitter or use a button of DuoControl Signal 111 accessories that must be programmed in Menu 2 5 OPEN CLOSE operation After pulsing in CLOSE position the drive starts and the door moves into end position OPEN Another impulse entry during drive has no effect and the door continues to open After impulse entry in OPEN position the door closes On impulse entry d...

Page 18: ...value of the operating mode 2 If desired adjust the setting with the aid of the OPEN B and CLOSE C buttons Menu value Open time without warning time 10 seconds 0 0 s 1 10 s 2 30 s 3 60 s 4 90 s 5 120 s 6 150 s 7 180 s 8 210 s 9 240 s Complete the installation procedure 1 Close the cover of the drive head 2 Check if the garage door operates properly and safely Refer to the section Maintenance Check...

Page 19: ...smitter Depending on the current position the garage door then goes to the OPEN or CLOSE position 2 If needed briefly press the button on the hand transmitter to stop the movement of the garage door 3 If needed press the button on the hand transmitter once again to make the garage door move in the other direction Note A button on the hand transmitter can be set with the function 4 minute light By ...

Page 20: ... worn Please consult your dealer of manufacturer Note When installing the system locking elements of the garage door operator are dismantled These should be reinstalled if the garage door has to be controlled manually over a longer period of time This way the garage door can be locked when closed Open or close the garage door other operation modes Possible operating modes see section Special setti...

Page 21: ...an external safety device such as a pass door The door does not close Interruption at STOP B or activation of an external safety device The door setting and learning cycle did not complete correctly You must use menu stages 3 and 4 to complete the door settings correctly and then complete the force learning cycle There is a permanent impulse signal at the start input Start signal is not detected o...

Page 22: ...power plug into the electrical socket Cycle counter The cycle counter stores the number of OPEN CLOSE actions powered by the drive To read the meter hold the button in for 3 seconds until you see a number The digital display shows the numbers starting from the highest to the lowest decimal place consecutively At the end a horizontal line appears on the display for example 3456 movements 3 4 5 6 ...

Page 23: ...Max load 500 N Connection values 230 V 50 Hz Power input Standby 4 W Max operation 160 W Max cycles hour 3 Max cycles day 5 Max cycles total 15000 Lighting LED 0 4 W Safety according to EN13849 1 Input STOP A Cat 2 PLC Input STOP B Cat 2 PLC internal force limit Cat 2 PLC Temperature range 20 C 60 C Protection class IP20 only for dry rooms Volume 70 dB A Manufacturer ALLMATIC by tormatic Via Dell ...

Page 24: ..._____________________ ________________________________________________ Testing the garage door drive Note An inspection is not the same as maintenance After an inspection the user must do any necessary maintenance Note For your safety we recommend that the door system be checked before initial use and as needed at least once a year in accordance with Check list for the garage door operator on page...

Page 25: ...indings 2 3 Fall protection State 2 4 Concentricity of T shaft State 3 0 Operator controls 3 1 Operator sliding rail bracket State Fastening 3 2 Electrical cables connections State 3 3 Emergency release Function State 3 4 Control devices push button hand transmitter Function State 3 5 Limit stop State Position 4 0 Safeguarding of crush and shearing zones 4 1 Force limit Stops and reverses 4 2 Prot...

Page 26: ...te or by a specialist company Monitoring the force limits The drive control unit features a 2 processor safety system to monitor the force limit In an end position or after restarting the integrated power disconnection is tested automatically Caution Closing force set too high can lead to personal injury Check the force limits every month as described in the section Checking force limit on page 14...

Page 27: ...with Annex VII part B and undertake to transmit it through our Documentation Department in response to a reasoned request by the competent national authorities Machine type Garage operator Machinery designation Sektio 500 Year of manufacture from 2019 Relevant EC EU directives Directive 2014 30 EU on electromagnetic compatibility as of 29 03 2014 Directive 2011 65 EU on restrictions on the use of ...

Page 28: ...ALLMATIC S r l Via dell Artigiano n 1 Z A 32020 Borgo Valbelluna Belluno Italy Tel 0437 751175 751163 r a ww allmatic com E mail info allmatic com ...

Reviews: