![Allmand Maxi-Power MP65-8C1 Operator'S Manual Download Page 16](http://html1.mh-extra.com/html/allmand/maxi-power-mp65-8c1/maxi-power-mp65-8c1_operators-manual_2903352016.webp)
15
• Do not fill fuel oil up to the cap level. When fuel
tank is filled to cap level, fuel oil will overflow due
to volume expansion caused by rise of ambient
temperature. Fuel may also spill due to machine
movement or transporting.
Checks Before Starting
Check Drain Water Sedimenter
If the red float (
D
) below the element (
C
) of the water
sedimenter rises to the upper level, it is necessary to drain
water.
1. Turn the fuel selector valve (
F
) to the OFF position.
2. Open drain valve (
E
) to drain accumulated condensed
water into an approved container (
G
).
3. After draining the condensate, close the drain valve.
4. Dispose of condensate according to local, state and/or
federal regulations.
C
D
F
E
G
Check Belt Tension
NOTICE
If belt tension too tight, it can cause shaft
breakage or shorten the life of a bearing. If too loose, the
belt may slip and will cause early breakage or damage to
the belt.
1. Visually check the belt for any cracks, wear, and other
defect. Replace if needed.
2. Depress the middle of the belt with a finger. Belt
deflection should be between 0.30 - 0.47” (8 - 12mm)
(
H
).
If adjustment is needed:
1. Loosen the alternator mounting bolt. Adjust until belt
deflection is 0.30 - 0.47” (8 - 12mm) when pressing
with a finger. Tighten securely.
2. Wipe any grease, oil, coolant, etc. from belt.
H
Check Oil Fence for Condensate
1. Remove the drain plug (
I
) and drain any condensate
accumulated inside the oil fence into an approved
container.
2. After making sure all condensate is drained, reinstall
the drain plug.
3. Dispose of condensate according to local, state and/or
federal regulations.
I
Clean Control Panel
Open control panel and check each breaker, terminal
plate and controller for any dust, sand and dirt
accumulated. Clean with compressed air.
Unit Operation
WARNING
• Keep the door shut and locked when machine is in
operation.
• If opening the door is necessary, be careful not to
touch rotating or hot parts. Burns or serious injury
could result.
NOTICE
Be sure to let unit warm up after starting for
smooth operation of the engine and the generator. Do
not operate the engine at full load immediately after
starting. This will shorten the equipment life.
• During machine warm-up, inspect the equipment
for any loose parts, fluid leakage, and other
issues.
• Make sure that monitor lamps are off.
Go to
Discount-Equipment.com
to
order your parts
Summary of Contents for Maxi-Power MP65-8C1
Page 8: ...7 I I I A B E H G F C D K J G o to Discount Equipm ent com to order your parts...
Page 39: ...38 ALLMAND COM Wiring Diagram Generator G o to Discount Equipm ent com to order your parts...
Page 40: ...39 Engine G o to Discount Equipm ent com to order your parts...
Page 41: ...40 ALLMAND COM G o to Discount Equipm ent com to order your parts...
Page 44: ...43 Addendum B Tire Safety Information G o to Discount Equipm ent com to order your parts...