45
TROUBLESHOOTING
TROUBLESHOOTING CHART
PROBLEM
POSSIBLE CAUSE
1. The lamp or lamps are burned out or broken or not screwed in securely.
2. Low electrical system voltage. Check volts and engine speed.
3. Too much power is being drawn from the auxillary outlets.
4. A circuit breaker or breakers are defective.
NO LIGHT
5. A capacitor or transformer has failed.
(ONE OR MORE
6. Plug and socket at light bar not securely pushed together and locked.
LIGHTS)
7. A loose connection in the back of the lamp socket in the lamp holder.
8. If the lamps have been on before. Lamps are not allowed time to cool
after last being lit. You must allow 15 minutes between the time the
lights are shut off and the time they are restarted.
9. A wrong style replacement lamp (requiring a different ballast) has been
installed.
10. Corrosion has occurred on the lamp bases.