3.1.2 Wayne “Vista” Dispensers
The following parameters must be set in the Wayne “Vista” dispensers in order for the
system to function correctly. Please note that the sections below only provide examples
of commonly used dispensers and their required settings. This section does not outline
all of the models and macro options available by Wayne.
Vista Dispenser
Model
Option #2 (
Macro)
Option #51
(Blend Ratios
)
V390 D1,
(non-blend)
5
N/A
V395 D1,
(variable blend)
13
Must match Point Of Sale
V580 D1,
(variable blend)
10
Must match Point Of Sale
V580 D3,
(variable blend)
11
Must match Point Of Sale
V590 Uni-hose,
(fixed blend)
10
Must match Point Of Sale
V590 D1,
(fixed blend)
7
Must match Point Of Sale
3.1.3
Wayne “Vista” Blending Dispensers
Variable Blenders
The NeXGen interfaces to the Wayne variable blenders. Examples are:
580 D1
- Single hose. Multi product dispenser without diesel.
580 D3
- Single hose. Multi product dispenser without diesel.
395
- Single hose + 1. Multi product dispenser with diesel.
Fixed Blenders
The NeXGen interfaces to the Wayne fixed blenders. Examples are:
590
- Multi hose, multi product dispenser without diesel.
590U
- Single hose, multi product dispenser without diesel. Uses
the same configuration as the 580.