NeXGen
Wayne Direct - Gilbarco / Installation and Start Up Guide
Copyright
2019 by Allied Electronics, Inc.
December 31, 2019
Page
2-13
2.3.7
Car Wash Communication
The NeXGen controller uses channel 3 to interface to the car wash controller. Six
different car wash controller pinouts are listed in the section below:
Ryko Code-A-Wash III
Ryko Code-A-Wash IV (S/N less than 166600)
Ryko Code-A-Wash IV (S/N 166600 or greater)
Unitec POS 4000
Unitec Portal Ti
Unitec Enterlink
Unitec Smart terminal
Kesseltronics Standard
Kesseltronics Advanced dual bay w/DB9 connection
Kesseltronics Advanced dual bay w/RJ45 connection
2.3.7.1
Ryko III and Kesseltronics Standard
NeXGen (CH 3) RJ45 adapter to the Ryko Code A Wash III and Kesseltronics Standard
(Part #N9348-ADP)
NeXGen
RJ45
Pins
CAT 5 Cable
(T568B Spec.)
RJ45
Adapter
Pins
Car Wash
DB9 Male
Pins
RXD 3
--------------
Wht/Grn
--------------
3 (Blk)
9 TXD
TXD 5
--------------
Wht/Blu
--------------
5 (Grn)
8 RXD
GND 8
--------------
Brown
--------------
8 (Wht)
7 GND
1 CTS
4 DCD
2.3.7.2 Ryko IV (S/N less than 166600), Unitec POS 4000, Portal Ti, Exacta, & DRB
NeXGen RJ45 adapter to the Ryko Code A Wash IV, Unitec POS 4000, Portal Ti, Exacta & DRB
(Part #N9344-ADP)
NeXGen
RJ45
Pins
CAT 5 Cable
(T568B Spec.)
RJ45
Adapter
Pins
Car Wash
DB9 Female
Pins
RXD 3
--------------
Wht/Grn
--------------
3 (Blk)
3 TXD
RTS 4
--------------
Blue
--------------
4 (Red)
8 CTS
TXD 5
--------------
Wht/Blu
--------------
5 (Grn)
2 RXD
DTR 7
--------------
Wht/Brn
--------------
7 (Brn)
6 DSR
GND 8
--------------
Brown
--------------
8 (Wht)
5 GND