![Allied LEISTER WELDPLAST S2 Operating Instructions Manual Download Page 6](http://html.mh-extra.com/html/allied/leister-weldplast-s2/leister-weldplast-s2_operating-instructions-manual_2901822006.webp)
Software and menu guide
The hand extruder Weldplast S2 is provided with a convenient user software, making work easier for the user. Tap
lightly on the keys to operate them.
Workspace functions
Menu selection functions
Menu selection
Menu selection / Back to workspace
Set contrast
Back to workspace (changes not saved!)
Heating on/off
Select and back to workspace
Change cursor position
Select
Selected value [+]
Cursor up / Selected value [+]
Selected value [–]
Cursor down / Selected value [–]
The device heats up to the last ideal temperature set directly after switching on the
main switch (1)
. When
the ideal temperature is reached, a counter on the status display counts back from 220 seconds to zero. After
this start-up process is complete, the device is ready to weld (status Ready*). The hand extruder takes around 6
minutes to reach its temperature range.
If the power is only turned off for a short time, the start-up process does not need to be repeated.
Motor disabled
Start-up waiting period: 220 seconds
Heating
M free
Ready*
Drive status
display (30)
Heating until ideal
values are reached
Motor release
Ready to weld
The temperature control prevents the hand extruder from being started while it is cold.
Welding preparation
Start window
After turning on the hand extruder
with the
main switch (1)
, the device
name and current software version
will be displayed for 3 seconds.
Workspace
The workspace shows the
parameters which are
currently set.
Setting the parameters in the workspace
The
cursor (31)
shows which parameters can be
set. After the device is switched on, the cursor
is situated on «
SPEED
». «
AIR
» or «
PLAST
» can
be selected with the
Select key (28)
and their
values can be changed using the
Up key (29)
or
Down key (27)
.
Set value
Set value
Set value