508226-01
Issue 2135
Page 7 of 38
MODEL NUMBER GUIDE
PHYSICAL AND ELECTRICAL DATA
Model
Voltage/Hz/Phase
Voltage
Range
Min.
Circuit
Amp.
Max. Over
Current
Device
(amps)
†
Compressor
Fan Motor
Refrig.
Charge
(oz) ††
Rated Load
(amps)
Locked
Rotor
(amps)
Rated
Load
(amps)
Rated
HP
Nom.
RPM
4AC13*18P-5
208-230/60/1
197-253
12.0
20
9.0
39
0.7
1/10
1010
61
4AC13*24P-5
208-230/60/1
197-253
17.5
30
13.4
53
0.7
1/10
1010
70
4AC13*30P-5
208-230/60/1
197-253
18.7
30
14.1
59
1.1
1/5
1090
68
4AC13*36P-7
208-230/60/1
197-253
20.1
35
15.2
70
1.1
1/5
1090
89
4AC13*42P-5
208-230/60/1
197-253
25.3
40
18.8
90
1.7
1/4
825
102
4AC13*48P-7
208-230/60/1
197-253
31.9
50
24.1
100
1.7
1/4
825
120
4AC13*60P-7
208-230/60/1
197-253
29.4
50
22.1
120
1.7
1/4
825
160
† Overcurrent protection device
† † Factory charge adequate for 15 feet of line set. Adjust per installation instructions.
UNIT DIMENSIONS (IN.) & SOUND RATINGS
Model No.
Dimensions
Shipping Weight (lbs.)
Sound
Ratings
(dBA)
A - Width
B - Depth
C - Height
Wire Guard
Louvered
4AC13*18P-5
24.25
24.25
25
130
138
76
4AC13*24P-5
24.25
24.25
25
132
140
76
4AC13*30P-5
24.25
24.25
29
142
154
76
4AC13*36P-7
24.25
24.25
29
141
149
74
4AC13*42P-5
28.25
28.25
29
187
199
79
4AC13*48P-7
28.25
28.25
33
181
192
79
4AC13*60P-7
28.25
28.25
29
194
205
80
Note:
Weights listed are unit weights with packaging
Dimensions listed are unit sizes w/o packaging
Minor Revision Code
Major Revision Code
Electrical
P - 208 - 230v/60hz/1Ph
Tonnage
18, 24, 30, 36, 42, 48, 60
Refrigerant
4 = R410A
AC
Air Conditioner
SEER
13
Tier
B = Wire Guard
L =
Louvered
4 AC 13 L 24 P - 7 A
Technical Specifications - 4AC13B/L*-5,7
Summary of Contents for 4AC13B
Page 31: ...508226 01 Issue 2135 Page 31 of 38 Figure 13 Wiring Diagram Wiring Diagram ...
Page 35: ...508226 01 Issue 2135 Page 35 of 38 Charge Labels Figure 14 4AC13 10 11 ...
Page 36: ...508226 01 Issue 2135 Page 36 of 38 Figure 15 4AC13 7 8 ...
Page 37: ...508226 01 Issue 2135 Page 37 of 38 Figure 16 4AC13 3 4 5 6 ...