508226-01
Issue 2135
Page 4 of 38
REFRIGERATION DATA
Outdoor Model
Charge (oz)
6
Refrigerant Connection
Refrigerant Line Size
Indoor Expansion
Device
Outdoor
Indoor (DTC)
7
Suction
Liquid
Suction
Liquid
Suction
Liquid
Piston
TXV
1
4AC13*18P-10/11
65
5/8
3/8
3/4
3/8
5/8 or 3/4
3
3/8 or 1/4 ²
0.053
H4TXV01
4AC13*24P-10/11
62
5/8
3/8
3/4
3/8
5/8 or 3/4 ³
3/8 or 1/4 ²
0.057
H4TXV01
4AC13*30P-10
82
3/4
3/8
3/4
3/8
3/4
3/8
0.063
H4TXV01
4AC13*30P-11
82
3/4
3/8
3/4
3/8
3/4
3/8
0.059
H4TXV01
4AC13*36P-10/11
84
3/4
3/8
7/8
3/8
3/4
3/8
0.072
H4TXV02
4AC13*42P-10/11
104
3/4
3/8
7/8
3/8
3/4 5
3/8
0.074
H4TXV02
4AC13*48P-10/11
124
7/8
3/8
7/8
3/8
7/8
3/8
0.082
H4TXV02
4AC13*60P-10/11
144
7/8
3/8
7/8
3/8
7/8 or 1-1/8 ⁴
3/8
0.090
H4TXV02
Note:
1 Required to achieve AHRI rating. If NA (Not Applicable) is in the piston column, then TXV is required.
2 Use 3/8 if over 24 feet of line set
3 Use 3/4 if over 24 feet of line set
4 Use 1-1/8 if over 24 feet of line set. Adapter provided with OD unit
5 Use 7/8 if over 24 feet of line set
6 Charged for 15 ft of line set
7 DTC = Designated Tested Combination
COOLING PERFORMANCE WITH DTC
1
Outdoor Model
Indoor Model
Capacity
(BTUH)
EER
SEER
4AC13*18P-10/11
E(C,M,U)1P24(A,B)+TDR
17600
11
13
4AC13*24P-10/11
E(C,M,U)1P24(A,B)+TDR
22800
11
13
4AC13*30P-10/11
E(C,M,U)1P24(A,B)+TDR
28000
10.7
13
4AC13*36P-10/11
E(C,H,M,U)1P36(B,C)+TDR
34000
10.5
13
4AC13*42P-10/11
E(C,H,M,U)1P43C+TDR
40000
10.7
13
4AC13*48P-10/11
E(C,H,U)1P49C+TDR
47000
11
13
4AC13*60P-10/11
E(C,H,U)1P49C+TDR
57000
10.7
13
1
DTC = Designated Tested Combination
NOTE:
For the latest ratings, please see
www.alliedratings.com or www.AHRIdirectory.org
Summary of Contents for 4AC13B
Page 31: ...508226 01 Issue 2135 Page 31 of 38 Figure 13 Wiring Diagram Wiring Diagram ...
Page 35: ...508226 01 Issue 2135 Page 35 of 38 Charge Labels Figure 14 4AC13 10 11 ...
Page 36: ...508226 01 Issue 2135 Page 36 of 38 Figure 15 4AC13 7 8 ...
Page 37: ...508226 01 Issue 2135 Page 37 of 38 Figure 16 4AC13 3 4 5 6 ...