Camera interfaces
100
Prosilica GX Technical Manual V2.3.1
Triggering during the Readout State
For applications requiring the fastest triggering cycle time whereby the camera
image sensor is exposing and reading out simultaneously, apply the
User Trigger
signal as soon as a valid
Trigger Ready
is detected. In this case,
Trigger Latency
and
Trigger Jitter
can be up to 1 row time since
Exposure
must always begin on an
Interline
boundary.
For a more detailed description of the trigger concept for advanced users and
special scenarios, see the
Triggering Concept
application note:
https://www.alliedvision.com/en/support/technical-papers-knowledge-
base.html
i