Camera interfaces
95
Prosilica GX Technical Manual V2.3.1
Lens control port
The lens control connector is a Hirose 3260-8S3. This connector provides the
signals necessary to control the iris, focus, and zoom of most commercially
available TV Zoom and Video-type auto-iris lenses. The cable side connector is
Hirose 3240-8P. The camera can be configured to operate lenses with unipolar
voltage requirements of 6 to 12 V or lenses that operate with bipolar voltages from
±6 V up to ±12 V. This voltage level can be controlled through software. The default
voltage is set to 6 V. The current capacity for each axis is 50 mA.
24 V
9.5 mA
2.4 K
Ω
23.2 V
217 mW
1.5
μ
s
22
μ
s
2
μ
s
37
μ
s
24 V
5 mA
4.8 K
Ω
23.8 V
120 mW
1.5
μ
s
12
μ
s
17
μ
s
105
μ
s
Pin
Signal
Direction
Description
1
Iris +
Out
Open Iris
2
Iris -
Out
Close iris
3
Focus +
Out
Focus far
4
Focus -
Out
Focus close
5
Zoom +
Out
Zoom out
6
Zoom -
Out
Zoom in
7
Auto iris, video type
Out
PWM Signal for Iris Control
8
External GND
---
External Ground for all lens control signals
Table 48: Lens connector definitions
Voltage specification
Do not exceed the lens manufacturers voltage specification.
Isolated Out
Power
OUT
ICC
R Load
V Load
R Power
Dissipation
T
1
T
2
T
3
T
4
Table 47: Trigger circuit values (Continued)
1
8
7
6
5
4
3
2