Patch SB251-13 for Software Release 2.5.1
C613-10361-00 REV M
The action of the MAJOR and MINOR relays
does not presently match the illustration
located alongside their connections.
This issue has been resolved by reversing
the action of the relays in software to match
the illustration shown on the right.
Please check that your alarm relays are still
appropriately connected.
The SET TRACE PORT command was not functioning correctly. Also, the
SHOW CONFIG DYNAMIC PING command was producing an incorrect
output format. These issues have been resolved.
The TRACE command was not working when using an IPv6 link-local
address. This issue has been resolved.
A memory leak occurred when some IPSEC processes failed. This issue has
been resolved.
Parallel forwarding PIM neighbours were not always sending PIM
Assert
messages following a neighbour re-boot. This was causing the transmission
of duplicate multicast data. This issue has been resolved.
PIM4 and PIM6 were not sending
Hello
packets if the HELLOINTERVAL
was not a multiple of 10. This is set with the ADD PIM INTERFACE, ADD
PIM6 INTERFACE, SET PIM INTERFACE, and SET PIM6 INTERFACE
commands. This issue has been resolved.
If a DVMRP interface was deleted and then added again, DVMRP routes
associated with this interface were not reactivated. This issue has been
resolved.
If the RP candidate advertising time was set to a non-default value with the
ADVINTERVAL parameter in the SET PIM command, the hold time in the
message was not being updated correctly. This issue has been resolved.
The output from the SHOW SWITCH PORT COUNTER command was
showing incorrect values for packets greater than 1519 bytes. This issue has
been resolved.
PCR: 03209
MODULE: ALARM
Level: 1
PCR: 03210
Module: PING
Level: 4
PCR: 03212
Module: IPV6
Level: 3
PCR: 03213
Module: IPSEC
Level: 3
PCR: 03214
Module: PIM
Level: 2
PCR: 03216
Module: PIM, PIM6
Level: 2
PCR: 03217
Module: DVMRP
Level: 2
PCR: 03222
Module: PIM, PIM6
Level: 2
PCR: 03223
Module: SWI
Level: 2