Appendix B - Continent Specific Parameters
Administration Manual (H.323 Version)
AT-VP504E FXO
81
Great Britain
Parameters
The following parameters apply if you have selected Great Britain as
location.
Table 35: Germany 2 Parameters
Parameter
Value
On – Off Sequence (s)
Elect. Levels
Dial Tone
425 Hz
0.2 – 0.3, 0.2 – 0.3, 0.2 – 0.8
-13 dBm
Busy Tone
425 Hz
0.17 – 0.43
-13 dBm
Ringing Tone
425 Hz
1.0 – 4.0, 1.0 – 4.0, 1.0 – 4.0
-13 dBm
Ring
75 VRMS, 25 Hz
1 – 4
Impedance
Z
R
= 220
Ω
+ 820
Ω
// 115 nF
Tbrl-Impedance
Z
N
= 220
Ω
+ 820
Ω
// 115 nF
FXO Line Attenuation (Input)
-7 dBr
FXO Line Attenuation (Output)
0 dBr
Table 36: Great Britain Parameters
Parameter
Value
On – Off Sequence (s)
Elect. Levels
Dial Tone
350+440 Hz
CONTINUOUS
-19 dBm
Busy Tone
400 Hz
0.375 – 0.375
-19 dBm
Ringing Tone
400+450 Hz
0.4 – 0.2, 0.4 – 2.0, 0.35 –
0.22 followed by 0.4 – 0.2,
0.4 – 2.0
-19 dBm
Special Information Tone
950 Hz
1400 Hz
1800 Hz
0.33
0.33
0.33 – 1.0
-19 dBm
Ring
62 VRMS, 25 Hz
1.0 – 4.0
Impedance
Z
R
= 300
Ω
+ 1000
Ω
// 220 nF
Tbrl-impedance
Z
N
= 370
Ω
+ 620
Ω
// 310 nF
FXO Line Attenuation (Input)
-9 dBr
FXO Line Attenuation (Output)
+3 dBr
Summary of Contents for AT-VP504E FXS
Page 1: ...AT VP504E FXO H 323 Administration Manual PN 990 11592 10 Rev C VoIPTalk...
Page 16: ...Chapter 1 Introducing the AT VP504E FXO Administration Manual H 323 Version AT VP504E FXO 8...
Page 76: ...Chapter 5 Software Upgrade Administration Manual H 323 Version AT VP504E FXO 68...
Page 100: ...Appendix C Gatekeeper Registration Logic Administration Manual H 323 Version AT VP504E FXO 92...
Page 112: ...Index Administration Manual H 323 Version AT VP504E FXO 104...