AT-8500 Series Fast Ethernet Switch Installation Guide
67
Warning
Do not strip more than the recommended amount of wire. (See
Figure 25.) Stripping more than the recommended amount can
create a safety hazard by leaving exposed wire on the terminal
block after installation.
17
Figure 25
Stripped Wire
4.
Connect the
frame ground
wire to the terminal marked with the
ground symbol by inserting the wire into the terminal and
tightening the connection with a flathead screwdriver, as shown in
Figure 26.
Warning
When installing this equipment, always ensure that the frame
ground connection is installed first and disconnected last.
18
Figure 26
Connecting the Stripped Wire
5.
Connect the
positive
feed wire to the terminal block marked (+).
6.
Connect the
negative
feed wire to the terminal block marked (-).
Warning
Check to see if there are any exposed copper strands coming from
the installed wires. When this installation is done correctly there
should be no exposed copper wire strands extending from the
terminal block. Any exposed wiring can conduct harmful levels of
electricity to persons touching the wires.
19
8mm ±1mm
(0.31in. ±0.039 in.)
36-60VDC