Step
Test Cycle Step
Display
Description
16
Cold and Detergent
Dispenser with "C1", "C2",
"C3" and "ES1" active
This step checks the cold water
valve and the detergent/bleach
valve along with external sup-
ply 1. The valves will shut off
once a low fill level has been
reached.
17
Hot and Softener
Dispenser with "C1", "C4" and
"ES2" active
This step checks the hot water
valve and the softener valve
along with external supply 2.
The valves will shut off once a
low fill level has been reached.
18
Pressure Sensor
Dispenser with "C1" active
This step turns on all water
valves and checks the analog
water level input. When the
water fill level is satisfied, the
water valves are turned off.
20
Overflow
"XX.Y" (inches)
This test checks the overflow
setting for the water level sen-
sor. All water and dispenser
valves are turned on. When the
overflow level is reached, the
water valves will automatically
turn off.
21
Low Agitate
RPM: XX and dispenser with
"ES3" active
The machine will perform a
low agitate.
22
Regular Agitate
RPM: XX and dispenser with
"ES4" active
The machine will perform a
regular agitate.
23
Drain/Pump
"Drain" or "Pump", Water Lev-
el: XX
XX is the current water level.
The control turns on the Elec-
tric Pump or the opens the
Gravity Drain.
24
Spin
"RPM: XX"
"MAX RPM: YY"
XX is the current basket speed.
YY is the maximum basket
speed reached. This step checks
the spin speeds. It steps through
spin speeds and maintains each
speed for a few seconds. After
1200 RPMs, the motor will
stop. This step lasts 4 minutes.
All Out of Balance checking is
done and if either the out of
balance switch is hit or the
check fails and needs to re-
spin, the time will be reset in-
definitely to allow the load to
be re-balanced so that it can
spin up and reach full speed.
Table 21
continues...
Diagnostics Menu
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
65
Part No. 806526ENR2
Summary of Contents for Quantum Platinum