Individual Diagnostic Tests
Test Name
Display
Description
Machine Config Test #4
XXX
XXX is the Machine Configuration #4
byte.
This test shows which dip switches are
set. 1 means the switch is on, 0 means the
switch is off .
0 = ON (120 VAC Supply)/OFF (240
VAC Supply)
2 = Unused
3 = ON (Payment System Present)/OFF
(Payment System Not Present)
4 = Unused
5 = Unused
6 = Unused
7 = ON (Heater Enabled)/OFF (Heater
Disabled)
8 = ON (Electric Pump)/OFF (Gravity
Drain)
Machine Config Test #5
XXX
XXX is the Machine Configuration #5
byte. This is unused.
Table 22
Configura-
tion Value
Life Test
Jumper
Present
Comm
Board "B"
Header
Present
Comm
Board "A"
Header
Present
Vend Con-
nection
Present
Coin Drop
#2 Present
Coin Drop
#1 Present
0
NO
NO
NO
NO
NO
NO
1
NO
NO
NO
NO
NO
YES
2
NO
NO
NO
NO
YES
NO
3
NO
NO
NO
NO
YES
YES
4
NO
NO
NO
YES
NO
NO
5
NO
NO
NO
YES
NO
YES
6
NO
NO
NO
YES
YES
NO
7
NO
NO
NO
YES
YES
YES
8
NO
NO
YES
NO
NO
NO
9
NO
NO
YES
NO
NO
YES
Table 23
continues...
Diagnostics Menu
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
69
Part No. 806526ENR2
Summary of Contents for Quantum Platinum
Page 2: ......