Individual Diagnostic Tests
Test Name
Display
Description
Show Drain Time Test
XXXXXs
XXXXX is the average drain time in sec-
onds. “s” is seconds. The average drain
time is calculated by taking the average of
the last ten (10) drain times from start of
the drain until the empty water level is
reached.
Purge Test
"Push Start to begin"
"Waiting"
"Running"
"Push Start to end"
The door locks and all water valves and
supply outputs turn on. The drain valves
open or the pump engages. If the key-
pad is pressed, the test ends and the door
unlocks after there is no water in the sys-
tem.
Leak Detection Test
"Push Start to begin"
"Filling", "Checking", "Result" then
"Pass", "Drain Leak" , "Valve Leak"
"Push Start to end"
The door locks. The drain valve closes or
the pump remains disengaged.
The Cold Water Valve Compartment 1
Valve and Compartment 2 valve turn on.
The Cold Water Valve turns off once the
fill reaches low water level. After a 10
second delay, the control records the cur-
rent water level and continues to monitor
the water level for two minutes. The dis-
play will show "Pass", "Drain Leak" or
"Valve Leak".
The drain valve opens or the pump en-
gages and the door unlocks.
DC Bus Voltage Test
XXX.X
XXX.X is the current DC Bus Voltage.
The door locks at the start of the test and
unlocks an the end of the test.
AC Mains Voltage Test
XXX.X
XXX.X is the current AC Mains Voltage.
Machine Config Test #1
XXX
XXX is the Machine Configuration #1
byte. This test shows a decimal value
whether or not coin drops and communi-
cation interfaces are connected and
whether the Life Test jumper is present. 1
means the item is present, 0 means the
item is not present.
Refer to next table for values.
Machine Config Test #2
XXX
XXX is the Machine Configuration #2
byte.
Machine Config Test #3
XXX
XXX is the Machine Configuration #3
byte.
Table 22
continues...
Diagnostics Menu
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT
68
Part No. 806526ENR2