34
37987
Section 5 Service Procedures
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the washer before servicing.
• Never start the washer with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the washer is properly grounded.
W003
WARNING
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
33. MOTOR SWITCH
a. Remove two screws from bottom edge of front
panel. Refer to Figure 25.
b. Pull bottom of panel away from washer until
hold-down clips (located on top flange of
panel) disengage from slots in cabinet top.
c. Remove two screws holding motor shield to
motor. Refer to Figure 24, and remove shield.
d. Disconnect wire harness from motor switch by
pressing down on locking tab on top of
connection block and at the same time pull
connection block away from motor switch.
Refer to Figure 22.
IMPORTANT: To avoid an open circuit, DO NOT
pull on terminal block wires when removing block
from motor switch as this could damage wires or
connection crimpings. Before attaching wire
harness connection block to motor switch, make
sure all male terminals on motor switch are straight
and are capable of accepting terminals from wire
harness connection block.
e. Remove screw holding motor switch to motor.
Refer to Figure 22, and remove switch.
f. Disconnect internal motor leads from motor
switch terminals.
NOTE: Refer to Wiring Schematics, Section 8 for
rewiring internal switch wires.
Figure 25
Hold-down
Clip
W22
3
S
E
3
A
Cabinet Top
Hold-down
S
crew
s
Front Panel
S
crew
s